Yamaha DRIVE 2 SUPER HAULER 2019 Owner's/Operator's Manual page 32

Table of Contents

Advertisement

MAINTENANCE
Electrolyte 1/8" Below
Bottom of Fill Well
Max. Level -
charged battery
Max. Level -
discharged battery
8
8-4
Fill Well
Electrolyte
1/8"
(3 mm)
Y-937c
Y-936a
• Before charging: only add distilled
water if fluid is below the top of the
plates, and then add just enough to
cover plates.
• After charging: open the vent
caps and look inside the fill
wells. Add distilled water until the
electrolyte level is 3 mm (1/8")
below the bottom of the fill well. A
piece of rubber can be used safely
as a dipstick to help determine this
level. Clean, replace and tighten all
vent caps.
NOTICE
Normal tap water contains
minerals which are harmful to a
battery; therefore, refill only with
distilled water.
3.
Using a hydrometer, check the
specific gravity of the battery
fluid in each cell against the
readings on the chart below.
Consult a Yamaha dealer if any
low readings are found, or if
readings vary more than one
point between cells.
Temperature
Satisfactory Uncorrected
Hydrometer Reading
°C
°F
48.9
120
43.3
110
37.8
100
32.2
90
26.7
80
21.1
70
15.6
60
10.0
50
4.4
40
-1.1
30
1.244
1.248
1.252
1.256
1.260
1.264
1.268
1.272
1.276
1.280
J2F