Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for leaks. Sparks or open flames will result in a fire or
explosion, which can cause serious bodily injury or death and
damage to property.
You will need: a soap and water solution and a rag or brush to apply it.
A) Mix soap and water.
B) Turn on gas supply at source.
C) Check for leaks by wetting fittings with soap and water solution and
watching for bubbles. If bubbles form, or if a bubble grows, there is a leak.
D) When leak checking is complete, turn gas supply off at source and
rinse connections with water.
Check:
E) Main gas line-to-manifold connections (1).
F) Side burner gas line-to-manifold connection (2).
m WARNING: If there is a leak at connection 1 or 2, retighten
the fitting with a wrench and recheck for leaks with soap and
water solution. If a leak persists after retightening the fitting,
turn OFF the gas. DO NOT OPERATE THE GRILL. Failure
to follow dangers, warnings and cautions contained in this
instruction sheet may cause a fire or an explosion resulting in
serious personal injury or death as well as damage to property.
Contact the Customer Service Representative in your area
using the contact information on our web site.
Log onto www.weber.com
G) Valves-to-manifold connections (3).
H) LP: Regulator hose-to-cylinder connection (4).
I)
LP: Regulator hose-to-regulator connection (5).
j) NG: Hose-to-quick-disconnect gas line connection (6).
m WARNING: If there is a leak at connections 3, 4, 5 or 6, turn
OFF the gas. DO NOT OPERATE THE GRILL. Failure to follow
dangers, warnings and cautions contained in this instruction
sheet may cause a fire or an explosion resulting in serious
personal injury or death as well as damage to property.
Contact the Customer Service Representative in your area
using the contact information on our web site.
Log onto www.weber.com
When leak checks are complete, turn gas supply OFF at source and rinse
connections with water.
m DANGER
®
.
®
.

CHECK FOR GAS lEAKS

m IMPORTANT: To do a proper leak check, control panel must
be off. after checking for leaks, reinstall control panel, wind
deflector and control knobs.
Gas Sources:
LP
3
1
4
5
2
NG
6