Desa Comfort Glow CGFB32CB Safety Information And Installation Manual page 8

Unvented (vent-free) universal firebox circulating louvered model
Table of Contents

Advertisement

Available languages

Available languages

Mantel clearances for Built-In
Installation
If placing custom mantel above built-in fire-
box, you must meet the minimum allowable
clearance between mantel shelf and top of
firebox opening shown in Figure 7. These are
the minimum allowable mantel clearances
for a safe installation. Use larger clearances
wherever possible to minimize the heating of
objects and materials placed on the mantel.
cAutIoN: close screens
before operation of vent-free
gas log heater. do not allow the
heater to touch or extend beyond
the fireplace screen.
If your installation does not meet the minimum
clearances in Figure 7, you must:
• raise mantel to an acceptable height,
f i r e - p a r t s . c o m
OR
• remove mantel.
Note:
All vertical measurements
are from top of fireplace
opening to bottom of mantel
shelf. All measurements
are in inches.
Facing material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments.
Firebox
Wire-mesh
Screen
Figure 7 - Minimum Mantel Clearances
for Built-In Installation
INstAllING BloWeR AccessoRy
You may install blower accessory GA3750A
with conventional installation (below) or with
built-in installation (see Built-In Installation of
Blower Accessory). To install blower accessory,
see instruction sheet included with the kit.
8
INSTALLATION
Continued
Mantel Shelf
10"
8"
6"
2
1
"
/2
13" 16"
19"
21"
Supplied
Firebox Hood
Must Be Used
at All Times
www.desatech.com
conventional Installation of Blower
Accessory
1. Install blower assembly per instruction
sheet included in blower accessory kit.
2. Before replacing bottom of firebox, route
blower power cord through hole in support
bracket in bottom of firebox and through
hole in side of firebox to grounded, three-
prong 120 volt electrical outlet (see Figure
8). Plug electrical cord into outlet.
3. Replace bottom of firebox.
Notice: a certified electrician
must connect electrical wiring to
duplex outlet for built-in instal-
lation. follow all local codes. in
absence of local codes, follow
the National Electrical Code,
ANSI/NFPA 70 (Latest Edition).
Blower
For
CGFB32C
Series
circulating
louvered
Blower Power
models
only
Cord
Figure 8 - Routing Blower Accessory
Power Cord for Conventional Installation
Built-In Installation of Blower Accessory
1. Install blower assembly per instruction
sheet included.
2. Before replacing bottom of firebox, re-
move screw holding duplex outlet to the
support bracket in the bottom of firebox.
Remove duplex outlet.
3. Clamp electrical cable into firebox
through smallest hole using strain relief
provided.
4. Route wires from electrical box through
hole in side of heater and hole in support
bracket (see Figure 9, page 9).
Electrical
Outlet
Side
Opening
Support Bracket
Opening
116548-01H

Advertisement

Chapters

Table of Contents
loading

Table of Contents