Minimum Clearances To Combustible Materials - Carrier 110 Series Installation, Start-Up, Operating And Service And Maintenance Instructions

Single stage 4 -way multipoise condensing gas furnace
Table of Contents

Advertisement

1. Disconnect all power to the furnace. Multiple disconnects
may be required. DO NOT TOUCH THE CONTROL
OR ANY WIRE CONNECTED TO THE CONTROL
PRIOR
TO
DISCHARGING
ELECTROSTATIC CHARGE TO GROUND.
2. Firmly touch the clean, unpainted, metal surface of the fur-
nace chassis which is close to the control. Tools held in a
person's hand during grounding will be satisfactorily dis-
charged.
3. After touching the chassis, you may proceed to service the
control or connecting wires as long as you do nothing to
recharge your body with static electricity (for example; DO
NOT move or shuffle your feet, do not touch ungrounded
objects, etc.).
4. If you touch ungrounded objects (and recharge your body
with static electricity), firmly touch a clean, unpainted metal
Outlet Choke Plate (provided with 40K BTUH furnaces only; see Note)
Drain Extension Tube (Z---pipe) (Provided separately in furnace)
NOTE: Only used for 40K BTUH furnaces from 0- -2000 ft. (0 to 610 M) above sea level for total equivalent vent lengths under 10 ft. (3 M)
POSITION
FRONT (Combustion air openings in furnace and in structure)
Required for service
All Sides of Supply Plenum
Top of Furnace
*Consult local building codes.
YOUR
BODY'S
Table 1 – Factory- -Supplied Installation Parts
DESCRIPTION
Air Intake Pipe Flange
Vent Pipe Flange
Pipe Flange Gaskets
Sharp Tip Screws (Vent and Inlet Flanges)
Vent Pipe Coupling
Vent Pipe Coupling Clamps
Pressure Switch Tube
Rubber Drain Elbow
Drain Tube Clamps
1/2---in. CPVC to 3/4---in. PVC Pipe Adapter
Gas Line Grommet
Junction Box Cover
Junction Box Base
Green Ground Screw
Blunt Tip Screws (Junction Box)
Thermostat Wire Grommet
Table 2 – Minimum Clearances to Combustible Materials for All Units
REAR
Sides
Vent
surface of the furnace again before touching control or
wires.
5. Use this procedure for installed and uninstalled (ungroun-
ded) furnaces.
6. Before removing a new control from its container, discharge
your body's electrostatic charge to ground to protect the
control from damage. If the control is to be installed in a
furnace, follow items 1 through 4 before bringing the con-
trol or yourself in contact with the furnace. Put all used and
new controls into containers before touching ungrounded
objects.
7. An ESD service kit (available from commercial sources)
may also be used to prevent ESD damage.
ACCESSORIES
See Product Data Sheet for a list of accessories for this product.
CLEARANCE
1 in. (25 mm)
*24 in. (610 mm)
*1 in. (25 mm)
1 in. (25 mm)
5
QUANTITY
1
1
1
2
10
1
2
1
1
4
1
1
1
1
1
3
1
1
0
0
0