TECHNICAL DATA

HOB DIMENSIONS
Width
Depth
BYPASS DIAMETERS
Rapid
Semi-rapid
Auxiliary
OTHER TECHNICAL DATA
TOTAL POW-
ER:
Electric supply:
Appliance cate-
gory:
Gas connec-
tion:
Appliance
class:
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER
Rapid
Semi-rapid
Auxiliary
BURNER
Gas original:
G20 (2H) 20 mbar
Gas replace-
G30 (3+) 28-30 mbar
ment:
G31 (3+) 37 mbar
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse
II2H3+
R 1/2"
3
NORMAL POWER kW MINIMUM POWER kW
3,0
2,0
1,0
594 mm
510 mm
Ø BYPASS 1/100 mm
42
32
28
0,75
0,45
0,33
8 kW
567 g/h
557 g/h
INJECTOR MARK
119
96
70