DESCRIPTION
System which makes it possible to perform installations in buildings with one or several points of entry and in compounds containing
several inner buildings. small-medium size.
The system can manage installations in:
- Buildings of up to 96 dwellings (monitors/telephones). up to 6 access or entry points.
- Compounds of up to 32 buildings with entrance panel with pushbuttons. up to 6 entry points or external access points
(gatehouses) to the compound
- Maximum number of houses in the compound: 96.
- Up to 6 access or entry points per building.
Up to 6 devices (monitors/telephones) per dwelling
2-wire connection, without connection polarity, both between panels and to the devices (monitors/telephones) in the dwellings.
All the telephones/connection brackets of each building are programmed from the main entrance panel of the building.
Confidentiality feature
Automatic switch-on feature with main panel (from telephone) or looped (from monitor).
Electronic call. call tone in dwelling varies depending on where the call is coming from (entrance panel of the building: main panel,
secondary panel; external entry point to the compound).
FUNZIONAMENTO
Due stati di funzionamento: sistema in stand-by e sistema attivo.
SISTEMA IN STAND-BY
I citofoni/monitor sono normalmente disattivi, in modo che le funzioni di comunicazione con il posto esterno e apertura della porta
siano disabilitate. I posti esterni sono in stand-by, con il sistema audio disabilitato e in attesa di eventuali chiamate o dell’eventuale
attivazione del sistema di accensione automatica da parte di un monitor.
SISTEMA ATTIVO
Il sistema passa dallo stato di stand-by allo stato attivo quando il citofono/monitor di un’abitazione riceve una chiamata da un posto
esterno o quando si attiva la funzione di accensione automatica da uno dei citofoni/monitor.
Funzione di autoaccensione
Sollevando la cornetta e premendo il pulsante di autoaccensone del citofono/monitor, si potra stabilire la comunicazione con la
pulsantiera principale dell’edificio, permettendo anche l’apertura dell’elettroserratura.
Durata dell’ autoaccensione: 60 secondi, fino a che non si riappende la cornetta o si riceve una chiamata.
Nel caso in cui ci sia il monitor, si potra visualizzare l’immagine captata dalla telecamera del posto esterno. Premendo ripetutamente
il pulsante di autoaccensione si attiverà questa funzione su ogni pulsantiera esterna. Consultare “Funzione di autoaccensione ad
anello”.
Ricezione della chiamata
Solo i citofoni/monitor associati al pulsante riceveranno la chiamata. Conferma della chiamata sul posto esterno. Se si solleva il ricevitore
di un altro citofono/monitor, si sentono toni intermittenti. Se il ricevitore del citofono/monitor è sganciato o se non vi è alcun
citofono/monitor associato a questo pulsante, il posto esterno emette toni intermittenti. Tempo di risposta: 30 secondi. Tempo di
conversazione massimo: 60 secondi. Prolungamento del tempo di conversazione: +60 secondi.
I posti esterni degli altri edifici restano in standby, in attesa che venga effettuata una chiamata. Se la chiamata avviene dall'accesso
esterno, il posto dell'edificio in cui si trova il citofono resta disabilitato (bloccato). La spia rossa dei posti rimanenti lampeggia durante
i tempo di risposta e conversazione, a indicare al visitatore che è attivato un altro posto esterno.
OPERATION
There are two operating states: system on standby and system active.
SYSTEM ON STANDBY
By default the telephones/monitors are inactive, so that the functions of communicating with the entrance panel and opening the door
are disabled. The entrance panels are on standby, with the audio system disabled while waiting for a call to be made or for a telephone
to activate the automatic switch-on system.
SYSTEM ACTIVE
The system changes from being on standby to being in the active state when the telephone/monitor in a dwelling receives a call from
an entrance panel or when the automatic switch-on feature is activated from one of the telephones/monitors.
Automatic switch-on feature
By picking up the receiver and pressing the automatic switch-on button of the telephone/monitor, you will be able to establish
communication with the main entrance panel of the building as well as to open the street door. Duration of automatic switch-on: 60
seconds, or until the receiver is put down or a call is made from the entrance panel.
If you have a monitor, you will also be able to see the image captured by the camera. Repeatedly pressing the automatic switch-on
button will activate this feature in each of the entrance panels of the installation. See “The Looped automatic switch-on function”.
Receiving a call
Only telephones/monitors associated to the pushbutton will receive the call. The call is confirmed at the entrance panel. If the receiver
of another telephone/monitor is picked up, beeping tones will be heard. If the receiver of the telephone/monitor is off the hook or if
no telephone/monitor is associated to that pushbutton, the panel will emit beeping tones. Time allowed to answer: 30 seconds. Maximum
conversation time: 60 seconds. Prolongation of conversation time: +60 seconds.
The panels of the other blocks will remain on standby until a call has been made. If the call is made from the external point of entry,
the entrance panel of the building where the telephone/monitor is located will be deactivated (blocked). The red light on this entrance
panel will blink during the answering and conversation periods, thereby informing any visitor that another panel is active.
79 | ABB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents