Poseidon NZ. Notice Poseidon reserves the right to alter product specifications and manual contents without notice Poseidon® (registered Trademark) Poseidon Emergency Egress Breathing Device Owner’s Manual Part No.PMPEEBD001b...
Three Levels of Caution Notices TheWARNINGindicatesaprocedureorsituation that,ifnotavoided,couldresultinseriousinjury ordeathtotheUser TheCAUTIONindicatesanysituationortechnique thatcouldcausedamagetotheproduct,andcould subsequentlyresultininjurytotheuser. TheNOTEisusedtoemphasizeimportantaspect, tips,andreminders. ProductDescription The PEEBD9393 and PEEBD1206consist of an advanced 1 stage Regulator, Cylinder and 2 Stage Regulator connected via a low-pressure hose. The products vary in cylinder design, via a single design 1 Stage Regulator with unique User / Filling protected ports - as follows Covert Military Users...
Page 5
Approvals/Qualification: EN250 Design Load plus 50% 6,750psi for 2 minutes Design Load plus 100% 9,000psi for 2 minutes prEN4856 Compass non-interference Compliant ANSTI Compliant Temperature Compliant Aviation Requirement Design Load times 3.75 16,875psi Cylinder Approvals ...
Page 6
Covert Military Users PEEBD1206 The 1 Stage Regulator is of a piston design, with integral filling port and dial indicator gauge. Stainless Steel and Chrome on brass components are used on the hose and swivel assemblies. Standard ¼ I.D. low-pressure hose of 20-inch (510mm)length. Chrome on brass fittings – Note the hose length can be ordered to any specific length required ...
Page 7
Overt Commercial Users PEEBD9393 The 1 Stage Regulator is of a Piston design, with integral filling port and dial indicator gauge. Stainless Steel and Chrome on brass components are used on the hose and swivel assemblies. Standard ¼ I.D. low-pressure hose of 20-inch (510mm)length. Chrome on brass fittings – Note the hose length can be ordered to any specific length required ...
Page 8
Overt Commercial Users PEEBD1206 The 1 Stage Regulator of Piston design, with integral filling port and dial indicator gauge. Stainless Steel and Chrome on brass components are used on the hose and swivel assemblies. Standard ¼ I.D. Low Pressure Hose of 510MM length. Chrome on brass fittings – Note the hose length can be ordered to any specific length required ...
General Pre-Cautions&Warnings The PEEBD (Emergency Escape Breathing Device)is intended for use only as an emergency device to assista crewmember or passengerin making an emergencyegress from a submerged aircraft, inverted vessel or inverted vehicle. DO NOT apply any form of petroleum-based lubricant, such as household oil or motor oil to any part of the PEEBD.
Page 10
DO NOT attempt to overfill the PEEBD1206beyond 3,000 PSI/ 207BAR at 70ºF/21ºC. Doing so may seriously weaken the cylinder and cause it to rupture,resulting in serious injury or death. DO NOT attempt to overfill the PEEBD 9393beyond 4,500 PSI/ 310 Bar at 70ºF/21ºC. Doing so may seriously weaken the cylinder and cause it to rupture,resulting in serious injury or death.
Component Identification (covert Military User system shown) Purge button Stage Regulator Stage Regulator “Off/On” Control Knob Pressure Stage Gauge Regulator “mouthpiece” Cylinder filling Port Air Cylinder PEEBD1206 Filling Adaptor for use with a Dive (SCUBA) Cylinder Low Pressure Hose...
General Information: Stage Regulator withCylinder Preparationand Setup Thepurposeofthismanualistofamiliarizeyouwiththecorrectsetup, filling, Inspection and Maintenance of the PEEBD. ThePEEBDispackagedfullyassembledandready touseafterithasbeen filledwithair by the purchaser Approved facility.Beforeusingithowever,itisveryimportanttocarefullyread and understand the procedures outlined in this manual for filling the PEEBD and performing a User Inspection. Only personnel trained in the use of SCUBA diving apparatus should use the PEEBD –...
Cylinder Marking Identification – PEEBD1206: 1. Before attempting to fill the PEEBD1206 (never fill the PEEBD9393 from a Dive cylinder), stage arecompletely dry – especially in the area surrounding the ensure the fill adapter and the 1 high-pressure port. 2. Examine the cylinder markings to verify that it is rated for a fill pressure of 3,000 PSI / 207 BAR.
Page 14
WARNING: DONOTattempttofillthePEEBD1206ifthecylinder markingsindicatethatitisassembledwithanon- standardcylinderratedforadifferentfillpressurethan 3,000 psi/207BAR.Doingsomayresultinrupture,explosioni ntheeventoffireoroverfilling.Instead,immediatelyret urntheunittoan OEM Approved facilityanddonot useunderanycircumstances. C y l i n d e r M a r k i n g I d e n t i f i c a t i o n - P E E B D 9 3 9 3 Examine the cylinder markings to verify that it is rated for a fill pressure of 4,500 PSI / 310 Bar.
CAUTION: Ifmoistureisfoundtobepresentinsidethe Filling Portopening,indicatingthatwatermayhaveente redthe PEEBD1 StageRegulator andcylinder,DONOTfillorattempttouse thePEEBDuntilithasreceivedcompleteinspecti onandany requiredservicebyan OEM Approvedfacility Filling the PEEBD1206from a DiveCylinder NOTE: ThePEEBD1206systemdoesnotincludeaDive Tankfill adapter.Theadapter(Part No PEEBD00600)maybepurchased separately(refertoComponentIdentification,p.10). WARNING: DONOTattempttoloosenorremovethe1 StageRegulator low pressure hosefittingorsafetyburstplugunderanycircums tances.Doingsocouldresultinadangerousmalfu nction ofthePEEBDwhichcouldresultinseriousinjuryo rdeath CAUTION: Thedial gaugeindicatoron the PEEBD isforreferenceonly.Use the fillsystemgaugeasindicatoroffillpressure.
Page 16
RED indicator visible below the Control Knob, indicating the “OFF” position The RED indicator can be easily viewed not matter the position of the Control Knob 3. Remove the Fill adaptor Plug and closely inspect the port opening to ensure that no debris, residue or moisture is present.
Page 17
6. Mate the threaded nozzle of the fill adapter withthe open fill port of the 1 Stage Regulator and turn clockwise by hand until the fit is snug. Hand tighten only asover tighteningthe fill adapter into the 1 Stage Regulator may cause damage. Loosen the fill adapter yoke screw as needed so that the dust cap can be removed from the inlet fitting and the yoke can be placed over the 1 Stage dive cylinder valve.
Page 19
7. While supporting the PEEBD1206with one hand, place the yoke of the fill adapter over the dive cylinder valve to align the inlet fitting flush against the valve O-Ring. Tighten the fill adapter Yoke screw clock-wise on to the small dimple on the backside of the dive cylinder valve.
Page 20
9. Support the PEEBD1206cylinder with one hand, and slowly turn the supply cylinder valve Control Knob counterclockwise to open and begin filling. As the PEEBD1206cylinder begins to fill, make sure the pressure indicator (dial gauge) shows that the cylinder is filling properly. NOTE: ThePEEBD1206 &...
Page 21
Immediatelyafterreleasingthepurgebutton,listen closelytoensurethatthe2 Stage Regulatordoesnotcontinuetoflowanyair. 13. While holding the 1 Stage Regulator and fill adapter secure, turn the PEEBD1206valve Control Knob clockwise until it stops, and the red indicator is visible. Turn the Control Knob of the supply dive cylinder valve clockwise until completely closed.
Page 22
Filling the PEEBD1206& PEEBD9393with a Compressor Fill Adapter CAUTION: DonotattempttofillthePEEBDseries, directlyfroma compressedairfillingstationunlessyouhavereceived thenecessarytrainingandauthorizationtodoso.Ifdone incorrectly,thisprocedureposescertainhazardswhich maycausesevereinjuryordeath. Caution –Never exceed the pressure shown on the Cylinder stamping - Always ensure the PEEBD cylinder reflects the pressure of fill NOTE: TheCompressorFillAdapter(Part PEEDB0979)isnot includedwithPEEBDan dmustbepurchasedseparately.
Page 23
5.While holding the 1 Stage Regulator and fill adapter secure, turn the PEEBDvalve Control Knob counterclockwise until it is completely open. When the Control Knob is in the open position, the Green indicator ring is visible. 6.Ensure that the PEEBDis supported and turn the compressor valve very slowly until it is slightly open to fill the cylinder with approximately 500 PSI / 34.5 BAR.
Page 24
7.To conserve the limited air supply of the PEEBD1206, perform a pre-issue inspection of the 2 Stage Regulator purge while it is connected to the supply cylinder as follows: b. Briefly depress the purge button to ensure that sufficient airflow is provided to clear the Stage Regulator.
Cover/Retainer for the 2 Stage Regulator Mouthpiece The 2 Stage Regulator incorporates a feature that enables the User to fit the Mouthpiece into a Cover/Retainer to be attached to the Survival Vest/Harness. This allows the 2 Stage Regulator to be easily removed from the Cover/Retainer when required for use The mouthpiece-to-body default position is horizontal which allows hose to route either to the right or left of the 2...
Prior to IssueInspection Before each use, the unit must be given a thorough visual inspection and functional test by a qualified User. V i s u a l l y I n s p e c t the low-pressure hose to ensure it is securely connected to its respective port on the 1 Stage and 2 Stage Regulator.
Page 27
Remove the protective rubber cover from the 1 Stage Regulator. Remove the Cover/Retainer from the 2 Stage Regulator. Pressurize the PEEBD by opening the Control Knob valve. Using a leak detection fluid lightly cover all connections on the PEEBD to check for any signs of leakage from the 2 Stage Regulator, hose, pressure gauge, safety disc assembly, 1 Stage Regulator, and cylinder neck (indicated by the...
Pre-FlightInspection Pre-Flight Inspections shall be performed on the PEEBD units prior to each flight by the aircrew member to whom the command has assigned. PEEBD Pre-Flight Inspection procedures are as follows: NOTE: Strict compliance with Pre-Flight and Post-Flight Inspections of the PEEBD unit shall be adhered to by all aircrew members using any PEEBD units.
Post-FlightInspection After use of the PEEBD, turn the Control Knob off (clockwise), so that red indicator ring is visible at the base ofthe Control Knob Check the PEEBD for signs of damage and contamination. If there are any signs of damage, report any discrepancies to maintenance personnel, remove the item from service, and clearly tag the item with a NON-RFI tag.
Care &Maintenance/Sustainment It is important to provide the correctpreventative maintenance/sustainment in order to ensure the best possible performance and reliability of the PEEBD.The following maintenance procedures should be performed routinely after each use of the equipment. After in-water training in either Salt or Chlorinated Water, the PEEBDshallbe cleaned, inspected, and prepared for the next use, or for storage.
Inspection &Service A PEEBD stored in an environmentally controlled facility, shall notbe considered to be ingood working order since it was last serviced. It is recommended that the PEEBD receive an Annual Inspection every 12-months by an OEM Approved Inspection facility. If the PEEBDis used regularly for training purposes in saltwater, chlorinated, or silted fresh water, the PEEBD will require an OEM Approved Inspectionevery three-months, or whenever it is suspected that moisture has entered the system.
Page 32
Hydrostatic Testing Waiver: a. The following Poseidon Spare Air Systems are not subject to US DoT Cylinder Hydrostatic Testing Standards (or any other published Standard) since cylinders not exceeding 2 inches outside diameter and less than 2 feet in length are excepted from volumetric expansion test.
Mouthpiece and Cover/Retainer shall be sanitized. When in service the 2 Stage Regulator Mouthpiece and Cover/Retainer should be sanitized at regular intervals to reduce the risk of bacterial contamination Poseidon Sanitizing Agent (P/N PEEBD10900) is available in a 5ltr concentrated volume.