Download Print this page

Pulse Output - Passive (Standard) 66-99-607; Pulse Output - Active (Re-Configured) 66-99-606 - Kamstrup 66-99-607 Installation Manual

Pulse divider

Advertisement

Pulse output – Passive (STANDARD) 66-99-607
PULSE DIVIDER – Passive
Type:
Cable length,
flow meter:
Cable length,
PULSE DIVIDER:
Pulse length:
Interval between
pulses:
2-wire connection: Voltage range
3-wire connection: Supply (9A)
Pulse output – Active (re-configured) 66-99-606
The PULSE DIVIDER can be re-configured to an active output.
NB!
PULSE DIVIDER – Active
Supplies from
Type:
the PULSE
Cable length, flow
DIVIDER (9A)
meter for calculator:
and calculator
Pulse length:
must not
be coupled
Intervals between pulses: Dependent on the actual pulse
together.
Voltage V
Open collector. 2- or 3-wire connection via the integrated
pull-up resistance of 33 k
Max. 10 m
Dependent on the calculator
100 ms (standard)
Dependent on the actual pulse frequency
Max. leak current
Min. R
load
Max. R
load
l
max
Flow chart PULSE DIVIDER
:
OH
3...6 VDC
1
A
30 k
1 M
3...10 VDC
0.2 mA
Active
Max. 10 m
100 ms (standard)
frequency
3.6 V ± 0.1 V
4

Advertisement

loading

This manual is also suitable for:

1084828