Installation Method - Breeze DVS Series User Manual

Table of Contents

Advertisement

We bring better air to life

7. INSTALLATION METHOD

The fan is designed direct connection to air duct.
Take care of direction of air flow shown by arrow stickers.
Check impeller rotation by hand for soft running. for external mounting weather
protection should be used. This should be designed to suit the installation and is
supplied by others.
Apply the markings for mounting of the fixing brackets onto the mounting surface.
Drill the holes and fasten the fan on the brackets by using appropriate fasteners.
Install the fan with bolts and nut to the building construction (refer to the right
picture).
Install the boom, flat washers,
nuts (customer need purchase
by yourself, you must use the
M8-M10 specifications).
Install firmly bolts and nuts when
it hanging down.
Nut
Flat washer
Size A bolt is 2-3
helicoidal than the Nut
8. OPERATION INSTRUCTION
Visual Inspection of Equipment
The equipment type and arrangement should be verified as ordered at once when it arrives at the jobsite. When a discrepancy
is found, the local Breeze Sales Representative must be notified immediately so that corrective action may be investigated, also
verify electrical conformance to specifications. Unauthorized alterations and unauthorized backcharges will not be recognized by
Breeze Fan.
After the unit has been assembled, installed and all utilities have been hooked up, the unit is now ready for operation.
Check
Before starting the unit, check the following:
Confirm that building supply voltage matches the voltage for which the unit is wired.
Check all piping and wiring penetrations
Made by contractors for water tightness. All penetrations must be made watertight to prevent water damage to the unit and
building.
Rotate the fan impeller manually to be sure that it is free to operate. Remove any dirt or debris that may have accumulated
during installation.
Inspect all fasteners to ensure that none have loosened during shipment.
Check all electrical connections for proper attachment.
Check casing and ductwork, if accessible, for obstructions and foreign material that may damage the fan impeller.
www.breeze.com.vn | breezefans@breeze.com.vn
Airflow
If you need prevent vibration,
please use the shockproof rubber
(customer need purchase by
yourself), its strength must be
able to carry this product's weight.
Install the bolt
Airflow
Casing to be installed
horizontally
Leading to the outdoor air duct
must remain slight slope.
Put the bags or canvas connect together
USER'S MANUAL
DVS SERIES
The product of hanging ceiling
structure and suspension
components must be able to
carry more than five times
intensity.
04

Advertisement

Table of Contents
loading