5. DIMENSION INFORMATION

A

6. ELECTRIC INSTALLATION

Electric Connection
The fan is designed for 220-240V/50Hz (single-phase).
The fan shall be connected to power supply by means of insulated, durable and thermal-resistant cords (cables, wires).
Electric wiring must be in accordance with technical connection regulations and local ordinances and national electric codes as
per enclosed wiring diagram in the terminal box or on the casing.
The recommended wire cross section is minimum 0.75 mm2.
The actual conductor cross-section selection must be based on its type, maximum permissible heating, insulation, length and
installation method (in the air, pipes or inside walls). Connect the cables to the terminal block incorporated inside the terminal
box located on the fan casing in compliance with the fan wiring diagram and the terminal designation. The terminal designations
are shown on the sticker inside the fan casing.
Check that supply is according to data on nameplate.
Insert cable according to the instructions in the junction box and seal it (Avoid water enter).The equipment connected ground
for motor protection according to the instructions - Unless the guarantee isn't accepted. Connect electric supply.
After connecting the wiring, install the terminal cover with screws.
Wiring Diagram
Black
AC
Red
Motor
Capacity
Brown
Yellow Green

7. INSTALLATION METHOD

Make a wooden frame and fix it on to the ceiling as picture reference.
Install and enclose the fan casing in the wooden frame, and then fix it up firmly with 04 self-tapping screws.
Connect the pipeline with the main part, and make it well-sealed with the self-adhesive tape (bandage). (Fix the ventilating
pipeline onto the ceiling, keeping the ventilating pipeline straight, without burden on the main part) no burden on the pipeline.
After connecting the power supply, turn on the switch, check whether there is abnormal condition, and then place spring in the
slot hole to fix the panel.
We must prevent the gas from the open airway or other firing equipment from back flowing into the room.
Ceiling joist
Fig 1.
www.breeze.com.vn | breezefans@breeze.com.vn
B
E
Terminals
L
Brown
FU
N
Blue
PE
Yellow
Green
Wooden frame
Enhance piece
USER'S MANUAL
Model
A
B
205
CPD 160
245
235
CPD 210
270
265
CPD 330
300
L
AC ~
220-240V
N
50 Hz
PE
Fig 2.
CPD SERIES
C
D
E
180
100
275
180
100
300
210
150
330
All dimensions in mm.
MCB
Fan
1
L
2
3
N
4
03