M2E068-CF10-65

3.2 Nominal data

Motor
M2E068-CF
Phase
1~
Nominal voltage / VAC
230
Frequency / Hz
50
Method of obtaining
me
data
Valid for approval/
CE
standard
-1
Speed (rpm) / min
2600
Power consumption / W
85
Power output / W
47
Current draw / A
0.38
Rated torque / Ncm
17.4
Mean starting torque
11.5
/ Ncm
Capacitor / µF
2
Capacitor voltage / VDB
450
Min. ambient
-25
temperature / °C
Max. ambient
45
temperature / °C
Starting current / A
0.74
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change

3.3 Technical description

Fan size
68 mm
Rotor surface
Painted black
Direction of rotation
Clockwise, viewed toward rotor
Degree of protection
IP44; installation- and position-dependent
as per EN 60034-5
Insulation class
"B"
Moisture (F) /
H0+
Environmental (H)
protection class
Installation position
Shaft horizontal or rotor on top; rotor on
bottom on request
Condensation
On stator side
drainage holes
Mode
S1
Motor bearing
Ball bearing
Touch current
< 0.75 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection
Thermal overload protector (TOP)
internally connected
with cable
Variable
Protection class
I (with customer connection of protective
earth)
Conformity with
EN 60335-1; CE
standards
Item no. 11403-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 4 / 8
Operating instructions

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing
; Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

; Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
Min. permitted
ambient temp. for
motor (transport/
storage)

4. CONNECTION AND STARTUP

4.1 Mechanical connection

; Check the device for transport damage. Damaged devices are not to
be installed.
; Install the undamaged device in accordance with your application.
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
8.8
+ 80 °C
- 40 °C
WARNING
Hot motor housing
Risk of fire
→ Ensure that no combustible or flammable materials are
located close to the motor.
CAUTION
Cutting and crushing hazard when removing motor from
packaging
→ Carefully remove the device from its packaging. Strictly
avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.