3.2 Nominal data

Motor
M2E068-DF
Phase
1~
Nominal voltage / VAC
115
Frequency / Hz
60
Method of obtaining
me
data
Valid for approval/
CE
standard
-1
Speed / min
3000
Power consumption / W
120
Power output / W
70
Current draw / A
1.15
Rated torque / Ncm
23
Mean starting torque
13
/ Ncm
Capacitor / µF
12
Capacitor voltage / VDB
220
Min. ambient
-25
temperature / °C
Max. ambient
55
temperature / °C
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change

3.3 Technical description

Weight
1.9 kg
Fan size
68 mm
Rotor surface
Rotor open, painted black
Direction of rotation
Right and left
Degree of protection
IP00
Insulation class
"B"
Moisture (F) /
H0 - dry environment
Environmental (H)
protection class
Installation position
Any
Mode
S1
Motor bearing
Ball bearing
Touch current
< 0.75 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection
Thermal overload protector (TOP) with
basic insulation
Protection class
I (with customer connection of protective
earth)
Conformity with
EN 60335-1; CE
standards
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.
Item no. 13002-5-9970 · ENU · Change 89188 · Approved 2016-04-18 · Page 4 / 8
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions

3.4 Mounting data

For screw clearance, see Chapter 3.1 Product drawing
; Secure the screws against unintentional loosening (e.g. use self-
locking screws).
Strength class of
screws
Any further mounting data required can be taken from the product drawing.

3.5 Transport and storage conditions

; Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
Min. permitted
ambient temp. for
motor (transport/
storage)

4. CONNECTION AND STARTUP

4.1 Mechanical connection

; Check the device for transport damage. Damaged devices are not to
be installed.
; Install the undamaged device in accordance with your application.

4.2 Electrical connection

8.8
- 40 °C
+ 80 °C
WARNING
Hot motor housing
Risk of fire
→ Ensure that no combustible or flammable materials are
located close to the motor.
CAUTION
Cutting and crushing hazard when removing motor from
packaging
→ Carefully remove the device from its packaging. Strictly
avoid shocks.
→ Wear safety shoes and cut-resistant safety gloves.
CAUTION
Possible damage to the device
If the device slips during installation, serious damage can result.
→ Ensure that the device is securely positioned at its place of
installation until all fastening screws have been tightened.
DANGER
Voltage on the device
Electric shock
→ Always connect a protective earth first.
→ Check the protective earth.

Advertisement