Sony Ericsson GR47 Integrator's Manual page 67

Hide thumbs Also See for GR47:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
Environmental specifications
Data Storage
LZT 123 7589 R2B
TECHNICAL DATA
Operating temperature
range (full specification)
Operating temperature
range (working)
Storage temperature
range
Maximum relative humidity
Stationary vibration,
sinusoidal
Stationary vibration,
random
Non-stationary vibration,
including shock
Bump
Free fall transportation
Rolling pitching
transportation
Static load
Low air pressure/high air
pressure
SMS storage capacity
Phone book capacity
-10 °C to +55 °C
-30 °C to +75 °C
-40 °C to +85 °C
95 % at +40 °C
Displacement: 7.5 mm
Acceleration amplitude: 20 m/s² and 40 m/s²
Frequency range: 2-8 Hz, 8-200 Hz, 200-500 Hz
Acceleration spectral density (m²/s²):
0.96, 2.88, 0.96
Frequency range:
5-10 Hz, 10-200 Hz, 200-500 Hz, 60 min/axis
Shock response spectrum I, peak acceleration:
3 shocks in each axis and direction;
300 m/s², 11 ms
Shock response spectrum II, peak acceleration:
3 shocks in each axis and direction;
1000 m/s², 6 ms
Acceleration: 250 m/s²
1.2 m
Angle: ±35 degrees; period: 8 s
10 kPa
70 kPa/106 kPa
40 in ME
In addition, the unit can handle as many SMS
as the SIM can store
100
67