Performance Data - Neptune TRICON E Installation And Maintenance Manual

Table of Contents

Advertisement

Parameter
T (op)
T (stg)
Vcc
R
L
Iout
1
These limits cannot be exceeded without possible damage.

Performance Data

Meter Size
Maximum
(in)
Flow Rate
(gpm)
5/8
20
3/4
30
1
50
1
1
/
100
2
2
160
1
For the High-Resolution Output of TRICON/E2 transmitters, multiply these values by 36, and for the TRICON/E3, multiply by 40.
TRICON/E/E2/E3 Transmitter Installation and Maintenance Guide
Table 3.4 All Models Absolute Limits
Description
Operating Temperature
Storage Temperature
Power Supply Voltage
Output Load (pulse output)
Output Current (pulse output)
Table 3.5 T-10 Disc Meters
Maximum
Minimum
Continuous
Flow Rate
Flow Rate (gpm)
(gpm)
10
1/4
15
1/2
25
3/4
1
50
1
/
2
80
2
1
Minimum
Maximum
0
85
-40
85
-30
30
1200
10
Number of
Pulse Output
Pulses per
@ Maximum
Gallon
1
Flow Rate (Hz)
578.1
192.70
322.6
161.30
150.8
125.67
67.57
112.62
37.50
100.00
Units
°C
°C
V
KΩ
mA
Flow Range
of 4-20mA
1
Output (gpm)
0–20
0–30
0–50
0–100
0–160
3-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tricon e2Tricon e3

Table of Contents