PLANNING -
Note: The high level of air flow of this appliance may affect the gas
flame on some types of gas cooktops. This is NORMAL and will
cause no harm, but can be corrected by lowering the speed of the
blower.

SPECIFICATIONS

VOLTS AMPS
CFM
120
4.0
500
3-1/4 X 10

TAKE MEASUREMENTS

1. Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The
Model HV303 will fit in most 30" wide cabinets and the Model
HV363 will fit in most 36" wide cabinets. However, it is
recommended that oversized cabinets be used for easier
installation.
2. Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference high-
lighted above. A countertop with (A) a raised lip and/or (B) a
backsplash may not allow enough flat countertop for a proper
installation. Note that 2" of flat countertop is required behind
cooktop and that 1-3/4" is necessary between the back edge of
the cooktop and the inside of cabinet back.
(continued)
DUCT

PLAN THE DUCTWORK

LEFT
DISCHARGE
1. This downdraft blower system is designed for use with 3-1/4"
x 10" ductwork (can be transitioned to 6" round). Three
different discharge directions are available with side-to-side
adjustment for accurate alignment of ductwork.
2. For best performance: Choose the ducting option which
allows the shortest length of ductwork and a minimum number
of elbows and transitions. Check location of floor joists, wall
studs, electrical wiring or plumbing for possible interference.
NOTE: The unit is shipped with the 3-1/4" x 10" discharge
facing DOWN. See "CHANGING BLOWER DIRECTION" on
page 3, if necessary.
6" ROUND
ELBOW
EQUALS 6 FT. OF
STRAIGHT DUCT
3. The system will operate most efficiently when the ductwork
does not exceed 40 feet of equivalent duct. The chart, above,
shows equivalent feet of elbows and transitions. The number
of feet of straight duct plus the equivalent feet of transitions
and/or elbows to be used should equal 40 feet or less.
NOTE: The equivalent feet of various roof and wall caps has
been taken into consideration. Do not include them in this
calculation.
PLAN THE WIRING
1. The downdraft blower system draws 4 AMPS and requires a
120 VAC, 60 Hz circuit.
2. The unit has a 2 ft. long power cord with a 3-pronged plug.
Plan to provide a grounded outlet in a location which will allow
the unit's power cord to reach. (Note: If the Model HV303 is
being installed in a 30" wide cabinet or the Model HV363 is
being installed in a 36" wide cabinet, the outlet cannot be
located on the back wall of cabinet.) Outlet may also be wall-
mounted, with access hole in cabinet.
2
DOWN
DISCHARGE
(as shipped)
3-1/4" X 10"
TO 6" RD.
TRANSITION
EQUALS 2
FT. OF
STRAIGHT DUCT
3-1/4" X 10"
O
90
ELBOW
EQUALS 8
FT. OF
STRAIGHT DUCT
RIGHT
DISCHARGE