Amana HV303 Instructions Manual
Amana HV303 Instructions Manual

Amana HV303 Instructions Manual

Downdraft blower systems

Advertisement

MODELS HV303 & HV363
DOWNDRAFT BLOWER SYSTEM
READ AND SAVE THESE INSTRUCTIONS
!
INTENDED FOR DOMESTIC COOKING ONLY
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the ad-
dress or telephone number in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel-burning equipment
to prevent backdrafting manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Do not use this range hood with an additional speed control
device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. Do not install this product with the activating switch directly
behind a burner or element. Minimum distance between the
switch and the edge of the burner should be 4 inches.
10. Loose-fitting or hanging clothing should never be worn when
operating this appliance. They may be ignited by burners/
elements on cooktop.
11. Children should not be left alone or unattended in the area
where this appliance is in use.
12. When flaming foods, turn the blower OFF. An operating
blower may spread the flames.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat
oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
cooking flaming foods.
3. Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for
the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
a
FOLLOWING
:
INSTALLER: Save this manual for Electrical Inspector and Homeowner to use.
HOMEOWNER: Use and Care Information on Page 5.
WARNING
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immedi
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
- a violent steam explosion will result.
4. Use an extinguisher ONLY if:
A.You know you have a Class ABC extinguisher, and you
already know how to operate it.
B.The fire is small and contained in the area where it
started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
a
Based on "Kitchen Firesafety Tips" published by NFPA.
13. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
3. Clean filters and grease-laden surfaces frequently.
4. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
5. Please read specification label on product for further informa-
tion and requirements.
PLANNING
This downdraft blower system is
designed to be used to exhaust
airborne contaminants when
cooking with a variety of gas or
electric cooktops. It can be
mounted in island, peninsula, or
conventional wall locations.
This unit can be easily installed
following these basic steps:
Cut out the countertop
opening.
Mount the unit in the
cabinet.
Connect the ductwork
and electrical.
Install the cooktop.
!
TYPICAL INSTALLATION
COUNTER
CHIMNEY TOP
TOP
COOK TOP
AIR
GEAR
VENT
MOTOR
COVER
BLOWER
BOX
120 VAC
GOUNDED
OUTLET
3-1/4" X 10"
DUCT CONNECTOR

Advertisement

Table of Contents
loading

Summary of Contents for Amana HV303

  • Page 1 MODELS HV303 & HV363 DOWNDRAFT BLOWER SYSTEM READ AND SAVE THESE INSTRUCTIONS INTENDED FOR DOMESTIC COOKING ONLY WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer.
  • Page 2: Plan The Ductwork

    1. Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The Model HV303 will fit in most 30" wide cabinets and the Model HV363 will fit in most 36" wide cabinets. However, it is recommended that oversized cabinets be used for easier installation.
  • Page 3: Mount The Unit

    PREPARATION CHANGING BLOWER DISCHARGE (Optional) The blower is shipped with its discharge facing DOWN. Follow these steps ONLY if: • the position of the blower discharge needs to be moved so ductwork does not interfere with floor joists, plumbing or wiring below. •...
  • Page 4: Install Ductwork

    INSTALL DUCTWORK CAUTION - BEFORE CUTTING HOLE IN CABINET FOR DUCT- WORK: Check for interference with floor joists, wall studs, elec- trical wiring or plumbing. BLOWER COLLAR SCREWS 1. Cut hole in cabinet as well as holes in wall or floor as necessary.
  • Page 5: Use And Care

    USE AND CARE Always turn the downdraft blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off. This will keep the whole kitchen cleaner and brighter.
  • Page 6: Service Parts

    Air Box Assembly (Model HV303) 97010992 Air Box Assembly (Model HV363) 98008150 Scroll Box Cover 98008157 Capacitor Strap 97009786 Filter Kit (Model HV303) (contains 2 filters) 97009787 Filter Kit (Model HV363) (contains 2 filters) 99090905 End Cap 99080295 Gearmotor 99110850...
  • Page 7 SERVICE PARTS Models HV303 & HV363 Downdraft Blower Systems...
  • Page 8 Warranty Limited One Year Warranty - Parts and Labor For one (1) Year from the original retail purchase date, any part that fails in normal home use will be repaired or replaced free of charge. Canadian Residents The above warranties only cover an appliance installed in Canada that has been certified or list- ed by appropriate test agencies for a compliance to a National Standard of Canada unless the...

This manual is also suitable for:

Hv363