Napa Carlyle DATA12 Manual page 8

1/4", 3/8", 1/2" dr. digital angle torque adaptor
Table of Contents

Advertisement

Available languages

Available languages

STEP 8: WHAT TO LOOK FOR
There are 12 LEDs to indicate the current torque
or angle reaching 80%, 85%, 90%, 95%, 97.5%
(green LED indication) and 100% (red LED
indication) of target torque/angle.
There is also a buzzer to indicate the reaching
level of target value. Interval sound means it
reaches over 80% and long sound means it
reaches over 100% of target value.
STEP 9: TORQUE/ANGLE VALUE WHEN ROTATES
Track mode Torque value
In Track mode, if a force is applied on adaptor,
LCD displays and tracks the current torque
value.
After releasing force, the LCD value will return to
target setting view.
Peak mode Torque value
In Peak mode, LCD displays the maximum
torque value.
After releasing force, the LCD shows the
maximum value. (flashing)
DATA12, DATA14, DATA38
100%
97.5%
((...((...
((((((((...
Apply
13.5 Nm
Release
force
Apply
13.5 Nm
12.0 Nm
24.48 Nm
Release
force
8
95%
90%
85%
...))...))
over 80%
...))))))))
over 100%
N-m
Current torque value
N-m
M T
Target torque
N-m
N-m
N-m
N-m
80%
T
P
Curre
P
P
P
Rev. 02/15/12