Remove Electric Box Assy - Gree GWH12AAB-K3NNA1A Service Manual

Refrigerant r410a
Table of Contents

Advertisement

Step

6. Remove electric box assy

a
Loosen the connection clasps between
Cold plasma generator and electric
box, and then remove the cold plasma
generator.
① Cut off the wire binder and pull out the
b
indoor tube temperature sensor.
② Screw off one grounding screw.
③ Remove the wiring terminals of motor
andstepping motor.
④ Remove the electric box assy.
⑤ Screw off the screws that are locking each.
Rotate the electric box assy. Twist off the
c
screws that are locking the wire clip and
loosen the power cord. Remove the wiring
terminal of power cord. Lift up the main
board and take it off.
Instruction: Some wiring terminal of this
product is with lock catch and other devices.
The pulling method is as below:
1.Remove the soft sheath for some terminals
at first, hold the circlip and then pull out the
terminals.
2.Pull out the holder for some terminals at
first (holder is not available for some wiring
terminal), hold the connector and then pull the
terminal.
66
Procedure
Cold plasma generator
Grounding
Indoor tube
screw
temperature sensor
Wire binder
Screw
Power cord
Circlip
Soft sheath
Screws
Step motor
Clasps
Electric box assy
Main board
Wiring terminal
of motor
Wiring terminal
of stepping motor
Screw
Wire clip
Holder
Installation and Maintenance
Service Manual
Electric box
Connector

Hide quick links: