Contrast Adjustment (Pd-117 Board) - Sony Digital Handycam DCR-TRV120 Service Manual

Hide thumbs Also See for Digital Handycam DCR-TRV120:
Table of Contents

Advertisement

4. RGB AMP Adjustment (PD-117 board)
Set the D range of the RGB driver used to drive the LCD to the
specified value. If deviated, the LCD screen will become blackish
or saturated (whitish).
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 3 of CN5502 (VG)
External trigger : Pin 4 of CN5502
(PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A5
A=3.59 ± 0.05 Vp-p (TYPE S model)
Specified Value
A=2.81 ± 0.05 Vp-p (TYPE C model)
Note: TYPE S model: DCR-TRV120/TRV120E: AEP, UK, EE,
NE, RU/TRV120P/TRV125E
TYPE C model: DCR-TRV120E: E, HK, AUS, CN, JE
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: A5, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
(The data of address: A5, should be "00" to "3F")
3)
Press the PAUSE button.
4)
Select page: 0, address: 01, and set data: 00.
A
Pedestal
Fig. 5-1-20
Pedestal
2H

5. Contrast Adjustment (PD-117 board)

Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: TYPE S 61 k model: DCR-TRV120/TRV120P
TYPE S 123 k model: DCR-TRV120E: AEP, UK, EE, NE,
TYPE C model: DCR-TRV120E: E, HK, AUS, CN, JE
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: AA, change the data and set the voltage
(A) between the pedestal (0 IRE) and 100 IRE to the specified
value.
(The data of address: AA, should be "00" to "7F")
3)
Press the PAUSE button.
4)
Select page: 0, address: 01, and set data: 00.
A
Pedestal
5-30
Ver. 1.1 2001. 01
Camera
Arbitrary
Pin 3 of CN5502 (VG)
External trigger : Pin 4 of CN5502
(PANEL COM)
Oscilloscope
D
AA
A=3.47 ± 0.07 Vp-p
(TYPE S 61 k model)
A=3.34 ± 0.07 Vp-p
(TYPE S 123 k model)
A=2.80 ± 0.07 Vp-p (TYPE C model)
RU/TRV125E
100 IRE
2H
Fig. 5-1-21