ADCP-96-159 Issue 4 March 2017 ® OmniReach DLX™ Mini Multi-Port Service Terminal User Manual 4-PORT 6-PORT 8-PORT 12-PORT 23544-B ADCP-96-159 Rev B www.commscope.com...
Page 2
Contents herein are current as of the date of publication. CommScope reserves the right to change the contents without prior notice. In no event shall CommScope be liable for any damages resulting from loss of data, loss of use, or loss of profits and CommScope further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
CommScoope Technical Assistance Center (refer to Section 7 on Page 20). Title ADCP Number CommScope OmniReach® DLX™ Connector and Adapter Cleaning Instructions 96-163 Universal Mounting Bracket Strand-Mount Installation Instructions 96-124 ADMONISHMENTS Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment.
23544-A Figure 1. Typical Mulitport Service Terminals The MST uses CommScope DLX adapters for the optical ports. A DLX adapter consists of a standard SC adapter that is enclosed within a protective housing. The housing provides sealed environmental protection for the adapter. The opening to each optical port is sealed with a threaded dust cap that prevents the entry of dirt and moisture.
Use the following procedure to unpack and inspect the MST and all accessories: 1. Open the shipping carton(s) and carefully inspect the MST and the attached cable. 2. If there are damages, contact CommScope (see Section 7) for an RMA (Return Material Authorization) and to reorder if replacement is required.
Page 18
ADCP-96-159 • Issue 4 • March 2017 After the UMB is mounted, install the MST in the UMB as shown in Figure 11. Insert the cable end of the MST into the UMB first and then push the front of the MST into the UMB until the latch snaps closed.
Figure 12. Securing Strand-Mounted MST 5 USING COMMSCOPE DLX HARDENED CONNECTORS AND ADAPTERS CommScope DLX hardened connectors and adapters provide sealed environmental protection for the subscriber drop cable connector, SC connector, and adapter mounted within the MST optical port. The following sections provide a description of the connector and adapter components and provide instructions for connecting or disconnecting the drop cable to/from the optical ports.
ADCP-96-159 • Issue 4 • March 2017 MST Adapter/Connector Cleaning Procedure Cleaning kit (FHD-ACC-CLNKIT1) is required for this procedure. Use the following procedure to clean the MST optical port adapters and the internal connectors: 1. Clean any debris from around the MST optical ports preferably using compressed air, to minimize contaminants introduced into the optical port.