PRESENTATION OF MANUAL INSTRUCTIONS FOR USE Technical Name: Equipment for tooth whitening and resins’ photopolymerizers. Trade Name: Curing Light Optilight Color Model: Optilight Color Brand: Saevo Manufacturer / Distribuitor: Alliage S/A Indústrias Médico Odontológica C.N.P.J. 55.979.736/0001-45 - Insc. Est. 582.002.897.114 Rod.
Page 3
INDEX 02 PRESENTATION OF MANUAL 04 IDENTIFICATION OF EQUIPMENT 07 MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CONSUMPTION 09 TECHNICAL SPECIFICATIONS 09 General features 10 Electromagnetic emission 14 Dimensions 15 Packing symbols 15 Product symbols 16 INSTALLATION OF EQUIPMENT 17 OPERATION OF EQUIPMENT 19 PRECAUTION, RESTRICTION AND WARNING 19 Recommendations for the equipment’s conservation 19 Transport conditions, warehousing and operation...
IDENTIFICATION OF EQUIPMENT Dear Customer Congratulations for your excellent choice. When buying equipments with “Saevo” quality, you can be sure of the acquisition of products with a technology comparable to the world’s best in its kind. This manual offers a general presentation of your equipment. Outlines important details that might orientate you in its correct use, as well as in the solution of small problems that might effectively occur.
The safety and efficiency of the LEDs, now with high energy emission, are available to all the clinical procedures that require light power for photo activation. The wavelength from 450nm to 470nm associated with the high energy emitted by Optilight Color enables the multi functionality of this device: •...
Page 6
• It does not require a forced ventilation system, therefore avoiding noise emission. We observe that the light emitted by the Optilight Color is completely contained within the absorption interval of the photo initiator and is, therefore, 100% used while conventional devices, which use halogen lamps have a big part not used in the process.
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CON- SUMPTION Continuous mode Visor “display” Ramp mode Pulse mode Time adjust button On / Off button Application mode selector button Green: Full charge Red: Loading 01 – Light conductor 02 - Handpiece 03 – Power supply unit 04 - Base A - Commands B - Indicative LED for the battery level...
Page 8
MODULES, ACCESSORIES, OPTIONS AND MATERIALS OF CON- SUMPTION Accessories that come with the product: HANDPIECE BATTERY OCULAR PROTECTOR BASE LIGHT CONDUCTOR POWER SUPPLY UNIT The content of this page is for informative purpose, so the equipment can present itself different from the illustration.
Electromagnetic emission Electromagnetic emission The Optilight Color is made to be used in the electromagnetic environments specified below. The client or the user of the Optilight Color must be sure that it is used in such environment. Emission test Compliance...
Guidelines and manufacturer's declaration - electromagnetic immunity The Optilight Color is made to be used in the electromagnetic environments specified below. The client or the user of the Optilight Color must be sure that it is used in such environment. Immunity...
Page 12
Guidelines and manufacturer's declaration - electromagnetic immunity The Optilight Color is made to be used in the electromagnetic environments specified below. The client or the user of the Optilight Color must be sure that it is used in such environment. Immunity...
Page 13
Recommended distances between portable and mobile RF communication equipments and the Optilight Color The Optilight Color is made to be used in an electromagnetic environment in which RF disturbances are controlled. The client or the user of the Optilight Color may help preventing electromagnetic...
TECHNICAL SPECIFICATIONS Packing symbols It determines the maximum Packing to be transported and quantity of boxes which can be / or stored avoiding humidity, stacked during transportation and rains and wet floor. storage “as per packaging”. The packing must be stored and Packing to be transported and / transported away from direct or stored with the harrows up.
INSTALLATION OF EQUIPMENT click 1-Before using it, please, 2- Insert the light conductor in 3-Insert the ocular protector on sterilize the light conductor, the handpiece until you hear a the light conductor. disinfect the handpiece, the slight click and feel that it was wire and the base.
OPERATION OF EQUIPMENT Press beep beep beep Press Press - Press the button to turn on the equipment (fig.1). - Select the application mode pressing the selection button (fig.2), which variations are: - Continuous: Maximum mode and continuous for light intensity (same luminosity from the beginning to the end of the polymerization).
Page 18
OPERATION OF EQUIPMENT Automatic shutdown: The equipment will turn off automatically when not in use for more than 3 minutes. For turning it on again, press the On / Off button. IMPORTANT: - Never address the light beam to the eyes; - Protect the visual field using the ocular protector;...
Page 19
- Don’t move it over irregular surfaces, protect it from rain and observe the maximum stack quantity specified in the packaging; ATTENTION: The equipment must be only used with the power cable supplied by Saevo, otherwise, it can cause the increasing of the emission or reducing of the equipment’s immunity.
- The equipment must only be operated by technicians duly qualified and trained (Dental Surgeons and Capacitated Professionals). - In case of a casual maintenance, only use the services of a Saevo’ Authorized Technical Assistance. - Do not submit the plastic parts to contact with chemical substances used in the dental treatments routine Such as: acids, mercury, acrylic liquids, amalgams, etc.
(failures, causes and solutions). If it is not possible to resolve the problem, turn off the equipment, remove the power supply cable from the socket and contact your representative (Saevo). Precautions to be adopted against foreseeable or uncommon risks, related to...
Page 22
For protecting your equipment, look for a Saevo technical assistance for periodic reviews as preventive maintenances. Corrective Maintenance Saevo states that the supplying of the circuits’ diagram, Part lists or any other information that permits the technical assistance by the user, can be requested, since previously agreed between the buyer and Saevo.
-Battery failure. -Get in touch with Saevo’ technical assistance. - T h e e q u i p m e n t i s n o t - N o n a p p r o p r i a t e d r e s i n -Buy the appropriated resin polymerizing the resins.
Among the care you have to take with your equipment, the most important is regarding of the spare parts replacement. To ensure the lifetime of your device, only replace original spare parts from Saevo. They have the assurance of the standards and technical specifications required by the Saevo representative.
Need help?
Do you have a question about the Optilight Color and is the answer not in the manual?
Questions and answers