WOODBURNING FIREPLACE
INSTALLATION & OPERATING
FOR RESIDENTIAL USE
Plumber:
Please refer to page 18 for gas connection information.
Framer:
Please refer to page 9 for framing specifications.
Heat-N-Glo, a Division of Hearth Technologies Inc.
20802 Kensington Blvd.
Lakeville, MN 55044
RHW-44
INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo RHW-44

  • Page 1 Heat-N-Glo, a Division of Hearth Technologies Inc. 20802 Kensington Blvd. Lakeville, MN 55044 RHW-44 WOODBURNING FIREPLACE INSTALLATION & OPERATING INSTRUCTIONS FOR RESIDENTIAL USE Plumber: Please refer to page 18 for gas connection information. Framer: Please refer to page 9 for framing specifications.
  • Page 2: Table Of Contents

    10. To ensure a safe fireplace system and to prevent 4. The RHW-44 woodburning fireplace must be the buildup of soot and creosote, inspect and clean the fireplace and chimney prior to use and installed with the Hearth Technologies Inc.
  • Page 3: Listings And Code Approvals

    However, installation of 20802 Kensington Blvd., Lakeville, MN 55044. WARNING! THIS HEAT-N-GLO FIREPLACE AND ITS COMPONENTS ARE DESIGNED TO BE INSTALLED AND OPERATED AS A SYSTEM. ANY ALTERATION TO OR SUBSTITUTION FOR ITEMS IN THIS SYSTEM, UNLESS ALLOWED BY THESE INSTALLATION INSTRUCTIONS, WILL VOID THE UNDERWRITERS LABORATORIES LISTING AND MAY VOID THE PRODUCT WARRANTY.
  • Page 4: Fireplace System Components

    RHW-44 WOODBURNING FIREPLACE C. FIREPLACE SYSTEM COMPONENTS The table below, together with the following pictures, show only those components which may be safely used with this fireplace. Cat.# Description RHW-44* Fireplace, includes outside air kit, integral grate and hearth protection strips...
  • Page 5 RHW-44 WOODBURNING FIREPLACE STRAIGHT ATTIC HEARTH EXTENSION GLASS DOORS INSULATION SHIELD INTEGRAL GRATE OUTSIDE AIR KIT (SUPPLIED) AK14 3-00 33147A...
  • Page 6 RHW-44 WOODBURNING FIREPLACE CHIMNEY SECTIONS CHIMNEY STABILIZER OFFSETS/RETURNS HTI CAT.# SL306 6" " SL312 12" " SL318 18" " HTI CAT.# SL324 24" " SL336 36" " SL315 15° SL348 48" " SL330 30° A=Actual length B=Effective length (length of chimney part...
  • Page 7 RHW-44 WOODBURNING FIREPLACE CHIMNEY TERMINAL CAPS & VENT SECTIONS TR344 ROUND TERMINAL CAP TR342 WITH STORM COLLAR ROUND TELESCOPING TERMINAL CAP ST375 SQUARE TERMINAL CAP TS345/345P SQUARE TERMINAL CAP CT35 CHASE TOP 3-00 33147A...
  • Page 8: Pre-Installation Preparation

    RHW-44 WOODBURNING FIREPLACE D. PRE-INSTALLATION PREPARATION 1. FIREPLACE LOCATIONS AND SPACE REQUIREMENTS Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 1.
  • Page 9: Framing The Fireplace

    RHW-44 WOODBURNING FIREPLACE 2. FRAMING THE FIREPLACE The RHW-44 fireplace will fit a framed opening of 45" the fireplace must be adhered to. Any framing across wide x 42" tall. The finished cavity depth must be no the top of the fireplace must be above the level of the less than 25 "...
  • Page 10: Hearth Extensions

    RHW-44 WOODBURNING FIREPLACE 2. HEARTH EXTENSIONS A hearth extension must be installed with all fire- A hearth extension of this construction may be cov- places. It is to protect the combustible floor in front of ered with any non-combustible decorative material the fireplace from both radiant heat and sparks.
  • Page 11: Sidewalls/Surrounds

    RHW-44 WOODBURNING FIREPLACE 4. SIDEWALLS/SURROUNDS Adjacent combustible side walls must be located a minimum of 20" from the fireplace opening. See Figure 7. If you are using a decorative surround constructed of combustible material, it must be located within the shaded area defined in Figure 7.
  • Page 12 RHW-44 WOODBURNING FIREPLACE After determining the offset dimension, refer to Example: Your “A” dimension from Figure 8 is 14 ⁄ ". Table 1 and find the “A” dimension closest to but Using Table 1, the dimension closest to but not...
  • Page 13: Chimney Height Requirements

    RHW-44 WOODBURNING FIREPLACE 2. CHIMNEY HEIGHT REQUIREMENTS chimney must be at least 2 feet above this reference (Above the roof line) point, but never less than 3 feet in height above the highest point where it passes through the roof.
  • Page 14: Step-By-Step Installation Of The Fireplace System

    RHW-44 WOODBURNING FIREPLACE F. STEP-BY-STEP INSTALLATION OF THE FIREPLACE SYSTEM WARNING! BEFORE STARTING, DO THE FOLLOWING: 1. WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. 2. KEEP HAND TOOLS IN GOOD CONDITION. SHARPEN CUTTING EDGES AND MAKE SURE TOOL HANDLES ARE SECURE.
  • Page 15 RHW-44 WOODBURNING FIREPLACE STEP 4 - Assembling Chimney Sections. to the ceiling joists from the bottom or fireplace side, EXCEPT when the space above is an insulated ceiling Attach either a straight chimney section or an offset or attic space. In this situation, the firestop spacer...
  • Page 16 RHW-44 WOODBURNING FIREPLACE WARNING! WHEN CHIMNEY SECTIONS EXCEEDING SIX FEET IN LENGTH ARE INSTALLED BETWEEN AN OFFSET/ RETURN, STRUC- TURAL SUPPORT MUST BE PROVIDED TO REDUCE OFF-CENTER LOADING AND PREVENT CHIMNEY SECTIONS FROM SEPARATING AT THE CHIMNEY JOINTS. STEP 10 - Marking the Exit Point of the Roof.
  • Page 17 RHW-44 WOODBURNING FIREPLACE STEP 14 - Installing the CAK4. When installing a CAK4 chimney air kit, follow the instructions provided with this accessory. Use of a CAK4 is required in Canada. STEP 15 - Installing an Outside Air Kit (standard).
  • Page 18 RHW-44 WOODBURNING FIREPLACE STEP 17 - Provisions for a Gas Log Set or Gas Log CAUTION: Lighter. Knockouts are provided on both sides of the fireplace WHEN USING A GAS LOG SET, for the connection of a certified gas log lighter or a dec-...
  • Page 19: Constructing A Chase

    RHW-44 WOODBURNING FIREPLACE G. CONSTRUCTING A CHASE In cold climates a firestop spacer should be A chase is a vertical box-like enclosure built around installed in an insulated false ceiling at the 8 foot the chimney and firebox. A chase may be constructed level above the firebox assembly.
  • Page 20: Installing A Terminal Cap On A Chase-Enclosed Chimney

    RHW-44 WOODBURNING FIREPLACE 2. Installing a Terminal Cap on a H. OPERATING Chase Enclosed Chimney. INSTRUCTIONS Construct a chase of desired materials maintaining a minimum 2" air space around the chimney. NOTICE: WARNING! SAVE AND PASS THESE OPERATING NEVER INSTALL A SINGLE WALL...
  • Page 21 IN IMPROPER VENTING (SMOKING) normal. OR AIR DILUTION. ALWAYS PRO- Use only a solid wood fuel or a listed Heat-N-Glo gas VIDE ADEQUATE MAKE-UP AIR. log set. Do not use a fireplace insert or products not specifically tested and listed for use in this fireplace.
  • Page 22 DM1136A, DM1136B, C1136A, C1136B, C1136C, C2136A, C2136B, C2136C or P1136B may be used on this fireplace. Before starting a fire in your RHW-44 fireplace, use the following check list: FLUE DAMPER. The flue damper is operated by pushing the handle up toward the top of the fire- box, which should place the damper in a fully open position.
  • Page 23 Combustible materials must not be stored in this to the fireplace system. Heat-N-Glo assumes no responsibility for the improper performance of the area. Combustible walls perpendicular to the front of fireplace system caused by inadequate draft due to the fireplace must be at least 20”...
  • Page 24 Chimney components and Glass Doors. If Heat-N-Glo is satisfied that any part or portion of the fireplace covered by this warranty is defective in material or workmanship under normal use and service as described in the operating instructions, Heat-N-Glo will take the following actions: Within the first five (5) years from the date of installation, Heat-N-Glo shall, at its option, replace or repair any such defect in material or workmanship, at Heat-N-Glo’s expense.