Click upper touch area until you see "AddrESS"
4

Modbus address information

For a stand alone 1-phase wallbox, recommended address is
002. This mode will paus the charging process if available current
in the system is below 6A. 6A is the minimum av EV can charge
according to standard.
Note: No need to to do any settings in the wallbox webinterface.
Modbus address 002 is the only adress that you can use if you
dont have any Wifi-module installed in your wallbox
Modbus address 002 is only valid for stand alone wallbox
installations.
Option 2, address 100. DLM settings in the webinterface are
required. Address 100 require an installed wifi-module in the
Master Wallbox.
Note: When use of Adress 100, the wallbox will not paus the
charging process if available current is below 6A.
If you want to monitor a 2nd mains cabinets, a 2nd DLM meter
can be installed in the 2nd mains cabinet. The modbus address
for the 2nd DLM meter should be 101. Both 100 and 101 will
not paus the charging process if available current in the system is
below 6A.
Note: DLM settings are required in the master wallbox
webinterface. Modbus address 100 and 101 require an installed
Wifi-module in your master wallbox.