Pb Battery Program; Charging Of Pb Battery; Discharging Of Pb Battery - UltraPower UP400AC Duo Instruction Manual

Multi charger built-in power supply
Table of Contents

Advertisement

PB BATTERY PROGRAM

This program is only suitable for charging Pb lead-acid battery with
nominal voltage from 2 to 20V, Pb lead-acid battery is a completely
different from NiMH/NiCD battery. These batteries can only deliver
current lower in comparison to their capacity. The same restriction
applies to the charging process consquently, the optimum charge
current can only be 1/10 of the capacity. Pb battery can not be used
for fast-charging. Please follow the instructions provided by the
battery manufacturer.

CHARGING OF PB BATTERY

-
+
DEC. INC.
Batt type
Start
Stop
Enter
Battery
Elapsed
Battery
voltage
time
type
Charge
current

DISCHARGING OF PB BATTERY

- +
DEC. INC.
Batt type
Start
Stop
Enter
Set up the charge current on the left and
nominal voltage on the right. Range of
current 0.1-20.0A(CH1), 0.1-12.0A(CH2),
the voltage should match the battery being
- +
DEC. INC.
charged. Press START/ENTER button for
more than 3 seconds to start charging.
>3 seconds
The screen display the real-time charging
status. Press START/ENTER button again
to store the parameter value you set. Press
BATT TYPE/STOP button to end the
Charged
capacity
program.
Set up the discharge current on the left and
nominal voltage on the right. Range of
discharge current is 0.1-8.0A(CH1),
- +
0.1-5.0A(CH2), the voltage should match
DEC. INC.
the battery being discharged. Press
>3 seconds
ENTER/START button for more than 3
seconds to start discharging.
18