WARNING

1) This product contains components, which are critical for X-radiation safety. Read the Service manual
carefully for proper replacement. Maximum 2nd anode voltage use high impedance meter, connect (-) to
chassis, use a high voltage lead from (+) to 2nd anode.
2) Critical Components are marked with the symbol of
X-radiation, replace only with same type and rating components.
3) Critical Components are marked with the symbol of # in the material list. For continued protection against
Low Radiation, replace only with same part number.
in the material list. For continued protection against