Internal Connectors; Power Requirements - Acer AM501 Service Manual

15-inch crt monitor
Hide thumbs Also See for AM501:
Table of Contents

Advertisement

4.8 Internal connectors

All internal connectors for the interconnection of sub assemblies must be distinct in their physical
characteristics or polarization so as to prevent any misconnection which may cause permanent
damage to the display.

4.9 Power Requirements

The display device shall maintain the specified performances in the range described below:
Frequency:
Voltage:
The following consumption requirements shall be met:
Power consumption: 75W for MPRII & VLMF Yoke
Current consumption: 1.2 Aac RMS
Note: Current and power consumption are the maximum values allowed in the voltage ranges describe
above.
4.9.1 Power Management
Table 5: Power Management
NO
STATE
1
ON
2
STAND-BY
3
SUSPEND
4
OFF
The states of power saving function shall be display by LED indication.
50/60Hz± 3Hz
90 to 264 Vac RMS
70W for NORMAL Yoke
STATE
HORIZONTAL
VERTICA
PLUSES
PLUSES
NO PLUSES
PLUSES
PLUSES
NO PLUSES
NO PLUSES
NO PLUSES
14
POWER SAVING
VIDEO
ACTIVE
NONE
BLANKED
<15W@90~240VAC
BLANKED
<15W@90~240VAC
BLANKED
<5W@90~240VAC

Advertisement