Temperature Display Range ........................41°F to 95°F (5°C to 35°C)
Temperature Control Range ........................44°F to 90°F (7°C to 32°C)
Load Rating .................................................1 amp per terminal, 1.5 amp maximum all terminals combined
Display Accuracy ........................................± 1°F
Differential ................................................... Heating is adjustable from 0.2°F to 2.0°F
Power Source.............................................. 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire
Operating Ambient Temperature ................32°F to +105°F (0°C to +41°C)
Operating Humidity .....................................90% non-condensing maximum
Dimensions .................................................4.72"W x 3.86"H x 0.98"D
Cooling is adjustable from 0.2°F to 2.0°F
(common wire) Battery power from 2 AAA Alkaline batteries