Download Print this page
Sealey AK9621EV Instructions

Sealey AK9621EV Instructions

Digital vernier calliper

Advertisement

Quick Links

DIGIT
DIGIT
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
1.
SAFETY INSTRUCTIONS
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to
!
when using tools and equipment.
DO NOT use AK9621EV if damaged.
"
Maintain AK9621EV in good and clean condition for best performance.
#
Keep the work area clean, uncluttered and ensure there is adequate lighting.
#
Keep children and unauthorised persons away from the work area.
#
DO NOT use the AK9621EV for any purpose other than for which it is designed.
"
DO NOT get AK9621EV wet or use in damp or wet locations, or areas where there is condensation. Keep AK9621EV clean
"
and dry using a dry cotton cloth only.
DO NOT dip or submerge the AK9621EV in any type of liquid.
"
DO NOT expose AK9621EV to bright sunlight or dust.
"
DO NOT dis-assemble AK9621EV. The AK9621EV must be checked by qualified service personnel only.
"
DO NOT apply any voltage to the AK9621EV i.e. with an electric marker pen.
"
The AK9621EV is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks.
#
Use AK9621EV in reasonably constant temperature conditions of approximately 20
#
When not in use, turn off and store gauge in a safe, dry, childproof location.
#
2.
INTRODUCTION & SPECIFICATION
Hardened and tempered stainless steel digital calliper with satin finish. Large LCD display with 11mm high figures for ease of
reading. Metric and Imperial calibration with conversion between the two. Zero setting control allows comparative measurement.
Supplied in robust storage case.
Specification
Resolution
Range
Accuracy
Functions
Messages
Battery life
Battery
Operational Temperature range
1
Internal Measure
2
On\mm\inch Button
3
Locking Screw
4
Fine Adjust Wheel
AL
VERNIER CALLIPER 0-150
AL
VERNIER CALLIPER 0-150
0.01mm (0.0005")
0-150mm (0-6")
±0.03mm/0.001"
Zero set, mm/inch select, incremental zero.
Flashing display = replace battery
Approx. two years (approx. one year in continuous service)
SR44 - 1.5V
0 - 40
5
6
7
8
INSTRUCTIONS FOR:
MODEL:
C
O
LCD Display
External Measure
Off Button
Zero Button
AK9621EV
AK9621EV
mm
mm
C.
O
9
Battery Cover
10
Depth Measure
11
Step Measure
/0-6"
/0-6"
Fig 1
AK9621EV - 1 - 290307

Advertisement

loading

Summary of Contents for Sealey AK9621EV

  • Page 1 VERNIER CALLIPER 0-150 /0-6” Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.
  • Page 2 INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, 01284 703534 www.sealey.co.uk Sealey Group, Bury St. Edmunds, Suffolk. 01284 757500 E-mail: sales@sealey.co.uk...