The Patient Kelly is a lifelike manikin, which realistically simulates a patient. It is specifically designed for training professionals in the practice of basic and advanced nursing techniques. The manufacturing quality of this simulator should provide many sessions of training when reasonable care and maintenance are practiced.
Tracheostomy Plug and Care: To remove tracheostomy plug, grasp firmly, lifting it up and out. To replace, press it into the opening. Laerdal Recommends: Use a size 6-tracheostomy tube. Opening will accommodate other sizes, but a size 6 is usually most suitable.
2. Work fingers under edge of plate and lift out. To insert: 1. Position plate over cavity. 2. Work edges into groove on torso cavity. Laerdal Recommends: Belly plate also contains urinary reservoir and colostomy stoma. To fill reservoir, remove colostomy stoma and fill, then reinsert stoma.
To remove legs, reverse procedure. Colon Reservoir: Colon reservoir inserts into pelvic cavity with narrow end downward and connector pointing out. This connector attaches reservoir to rectal valve on genitalia. Reservoir should be removed from manikin, inverted and drained completely before storage. 301-00001 Laerdal...
Genitalia – Both male and female genitalia have been provided for urinary catheterization and enema training procedures. Valve tubes, with a screw cap on Laerdal one end, will connect urethra and anus Recommends: to corresponding reservoirs. This cap must be connected to genitalia openings.
2. Pull upper portion of genitalia back to remove pelvic support pin. Belly plate, genitalia with connectors and colon reservoir may now be removed simultaneously. Urinary Catheterization and Enema Simulation – Laerdal After several uses, catheter Recommends: may “hang” when water has washed away lubricant, causing Catheters should be friction and binding.
5. Articulating parts will benefit from a light application of talcum powder prior to training sessions. 6. Store properly between teaching sessions. Cautions and Warnings This product contains Natural Rubber latex which may cause allergic reactions when in contact with humans. 301-00001 Laerdal...
Replacement Parts Product Number: Description 301-00001 Patient Kelly 380460 Genitalia, Blank-Adult Male 380471 Plug, Belly plate-Adult 380475 Pin, Pelvis 380600 Leg Assembly, Left Adult 380650 Leg Assembly, Right Adult 380800 Arm Assembly, Left Plain Adult 380801 Hand, Left Adult Male...
Page 13
Stoma, Soft Style W/Thru Hole 300-05150 Arm Assembly, Left Plain Adult 300-10250 Chest plate, Hospital Plain Adult Male 301-00150 Head Assembly, Hard w/Trach Opening Adult Male Please contact Customer Service Representatives for more information on Replacement Parts in other skin tones. 301-00001 Laerdal...