RS-232C command table

How to read the command table
Command:
Command field (See page 35.)
Direction:
W When the "Parameter" is set in the parameter field (see page 35), the command functions as described
under "Control/Response Contents".
R The returned value indicated under "Reply" can be obtained by setting "????", "
(repeater control) in the parameter field. (See page 35.)
Parameter:
Parameter field (See page 35.)
Reply:
Response (Returned value)
* :
"●" indicates a command which can be used in standby mode regardless of the POWER SAVE MODE setting.
"○" indicates a command which cannot be used in standby mode when POWER SAVE MODE is set to ON.
"–" indicates a command which cannot be used in standby mode regardless of the POWER SAVE MODE setting.
Power control/Input mode selection
Function
POWER CONTROL
INPUT MODE SELECTION
Command
Direction
Parameter
POWR
W
0
1
R
INPS
W
0
1
2
3
10
13
14
21
R
Controlling the Monitor with a PC (RS-232C)
Reply
Control/Response contents
Switches to standby mode.
Returns from standby mode.
0 Standby mode
1 Normal mode
2 Input signal waiting mode
Toggle change for input mode. Terminals not selected in INPUT SELECT
cannot be selected.
DVI-D
D-SUB[RGB]
"ERR" when other than RGB is selected for D-SUB of INPUT SELECT.
D-SUB[COMPONENT]
"ERR" when other than COMPONENT is selected for D-SUB of INPUT
SELECT.
HDMI1
HDMI2
DisplayPort
OPTION
"ERR" when nothing is attached in the expansion slot.
1 DVI-D
2 D-SUB[RGB]
3 D-SUB[COMPONENT]
10 HDMI1
13 HDMI2
14 DisplayPort
21 OPTION
?" or "???+"
*