Samsung AM072/096/120/144FXVAFH Service Manual page 279

Table of Contents

Advertisement

How to check the view mode using a tact switch
AM038/048/055KXWD
K3 (Number of press)
1 time
K4 (Number of press)
1 time
2 times
Target frequency (Compressor 1)
3 times
4 times
5 times
6 times
IPM temperature (Compressor 1)
7 times
8 times
9 times
10 times
11 times
12 times
13 times
14 times
15 times
Current frequency of the compressor 1
16 times
17 times
K4 (Number of press)
1 time
2 times
3 times
4 times
5 times
6 times
8-16
Key operation
Initialize setting (Reset)
DVM S water cooled view mode
View mode 1
Key operation
Outdoor Capacity
High pressure (kg/cm2)
Low pressure (kg/cm2)
(1 second value)
Discharge temperature
(Compressor 1)
CT sensor value (Compressor 1)
Suction temperature
Cond Out temperature
Liquid temperature
TOP temperature (Compressor 1)
Water temperature
Main EEV step
ESC EEV step
Address of master indoor unit
Temperature of control box
To enter the view mode 2 : Press the K4 during 3 seconds.
View mode 2
Key operation
Main version
Water Hub version
Inverter 1 version
EEP version
Receiving device
Automatic address
Receiving device
Manual address
(cont.)
Display on 7-segment
Same as Initial state
Display on segment
SEG 1
1
16 Horsepower
2
3
4
5
6
7
8
9
A
B
C
D
E
F
When master indoor unit is not set
G
When indoor unit No.1 is set as master indoor unit
H
Display on page
Page 1
MAIN
Version ( ex) 1412)
HUB2
Version ( ex) 1412)
INV1
Version ( ex) 1412)
EEP
Version ( ex) 1412)
SEG1, 2
AUTO
Indoor unit : "A", " 0"
MCU : "C", " 1"
MANU
Indoor unit : "A", " 0"
SEG 2,3,4
0,1,6
120Hz
1,2,0
15.2K
1,5,2
4.3K
0,4,3
87 °C
0,8,7
87 °C 0,8,7
2 A
0,2,0
-42 °C
-,4,2
-42 °C
-,4,2
87 °C 0,8,7
87 °C
0,8,7
-42 °C
-,4,2
2000
2,0,0
300
3,0,0
120Hz
1,2,0
BLANK, N, D
0, 0,
1
-42 °C
-,4,2
Page 2
SEG3, 4
Adress
( ex) 07)
SEG3, 4
Adress
( ex) 15)
Samsung Electronics