Download Print this page

Harman AMX Modero X MXD-2000XL-PAN Series Quick Start Manual page 2

Wall mount touch panel

Advertisement

4.
Remove any knockouts as needed on either long dimension of the Backbox to facilitate
incoming wiring and pull the wiring through the resultant holes.
5.
Push the Backbox into the wall opening. Insure that the locking tabs lie flush against the
Backbox.
6.
Extend the locking tabs on the sides of the Backbox by tightening the screws inside the
box until snug. Apply enough pressure to the screw head to keep the box flush with the
wall: this ensures that the locking tabs will tighten up against the inside of the wall.
7.
For additional strength, #4 mounting screws (not included) may be secured through the
mounting holes located at the left and right sides of the panel (FIG. 4). In order to
prevent damage to the touch panel, make sure that these are flush with the Backbox.
8.
Insert each connector into its corresponding location along the back of the device.
9.
Test the incoming wiring by attaching the panel connections to their terminal locations
and applying power. Verify that the panel is receiving power and functioning properly to
prevent repetition of the installation.
Remove power before continuing with the installation.
Note: Do not disconnect the cables from the touch panel. The panel must be installed with
the cables attached before being inserted into the drywall.
Note: Conf igurations that use the limited access USB port on the side of the connector
box may require a right angle mating connector (not included).
10.
Insert the four temporary mounting posts of the panel into the openings on the Backbox
and slide the panel onto the Backbox. This will temporarily hold the panel during the rest
of the installation (FIG. 5).
Side cover
4X Mounting posts
MXD-2000XL-PAN INSTALLATION (LANDSCAPE)
FIG. 5
WARNING: When installing the panel, do NOT press on or near the center of the panel. Too
much stress at the center may damage the touch screen surface. When installing the
panel, pressure should be applied toward the ends of the panel ONLY.
11.
Use the six provided screws, three at each end, to secure the touch panel to the Backbox
(FIG. 5). Use only the provided screws, as other screws may damage the touch panel.
12.
Snap the side covers onto each end of the touch panel.
13.
Reconnect the terminal Ethernet and USB to their respective locations on either the
Ethernet port or NetLinx Master.
Panel Connectors and Wiring
Connectors are located on the underside of the MXD-2000XL-PAN. The Micro-USB port is used
for camera video output. A second, limited access USB port is accessible on the back side of
this cover.
Wiring Guidelines
The MXD-2000XL-PAN uses a 13.5V
panel via the 2-pin 3.5 mm captive wire PWR connector. Use the previously provided power
requirement information to determine the power draw. The incoming PWR and GND wires from
the power supply must be connected to the corresponding locations within the PWR
connector.
Note: Apply power to the panel only after installation is complete.
Note: Connecting power to the MXD-2000XL-PAN should be done using the included 2-pin
3.5mm captive wire connector included with the device. This connector uses retaining screws
(instead of the pins on each side of standard captive wire connectors); using excessive force to
insert a standard captive wire connector may damage the device.
Wiring a Power Connection
To use the 2-pin 3.5 mm captive wire connector with a 13.5V
incoming PWR and GND wires from the external source must be connected to their
corresponding locations on the connector (FIG. 6). The connector uses locking screws to
insure a connection to the device, so make sure to insert and tighten the screws before
applying power.
1.
Insert the PWR and GND wires into the terminal end of the 2-pin 3.5 mm captive wire
connector cable. Match the wiring locations of the +/- on both the power supply and the
terminal connector.
© 2015 Harman. All rights reserved. Modero X and Modero X Series, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are
registered trademarks of HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks
of their respective companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
Last Revised: 6/22/2015
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
4X Mounting post openings
Wall
6X 4-40 X 1/4" LONG FLAT HEAD
TORQUE TO 5±.2 IN LBS
-compliant power supply to provide power to the
-compliant power supply, the
PWR +
To the Touch Panel
GND -
NETLINX POWER CONNECTOR WIRING DIAGRAM
FIG. 6
2.
Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing
so may strip the threads and damage the connector.
3.
Verify the connection of the 2-pin 3.5 mm captive wire connector to the external
-compliant power supply and apply power.
13.5V
Powering On/Off X Series Panels
X Series touch panels may be powered on by touching and holding the Sleep button. To power
off the panel, press and hold the Sleep button, and select Power Off.
Conf iguration and Programming
X Series touch panels are equipped with a Settings menu that provides the ability to configure
various features on the panels. To access the Settings menu, press and hold the Sleep button,
and select Settings.
Note: Information on the Settings menu, panel conf iguration, and programming is provided in
the Modero X Series Programming Guide, available at www.amx.com.
Setting the Panel's Device Number and Device Name
1.
In the Settings menu, select NetLinx. This opens a password keypad.
2.
Enter the panel password into the keypad (the default is 1988) and select OK to access
the NetLinx page.
3.
Press Device Number to open the NetLinx editing window.
4.
Enter a unique Device Number assignment for the panel and press OK.
5.
Enter a unique Device Name assignment for the panel and press OK.
Conf iguring the Panel's IP Address
Side
These steps configure the panel to communicate with a network; it is still necessary to
cover
connect to the NetLinx Master (see Connecting to a NetLinx Master below).
Network Communication via DHCP
1.
In the Ethernet page, press DHCP/Static field to open the DHCP/Static window. Note
that DHCP is the default setting.
2.
Select Host Name, enter the new host name
3.
Press OK to save changes.
Network Communication via Static Address
1.
In the Ethernet page, press DHCP/Static to open the DHCP/Static window.
2.
Select Static to open the Static IP window.
3.
Press any field to open a keypad or keyboard (depending on the field), and enter the
appropriate network address information.
4.
Press OK to save your changes and return to the Ethernet page.
Connecting to a NetLinx Master
To establish the type of connection to make between the panel and the NetLinx Master:
1.
In the NetLinx page, press Mode to choose the connection mode (URL, Listen or Auto):
CONNECTION MODES
Mode
Description
URL
The device connects to the
target Master's IP address via a
TCP connection.
Listen
This mode allows the panel to
"listen" for the Master's
communication signals.
Note that in this mode, the
System Number and Master
IP/URL fields are read-only.
Auto
Use this mode when both the
panel and the NetLinx Master
are on the same Subnet.
2.
If password security is enabled on the target Master, enter the Username and Password:
a.
Select Username to open the NetLinx window.
b.
Enter the Username and Password required by the Master.
c.
Press OK to save changes and return to the NetLinx page.
Related Software and Additional Documentation (at www.amx.com)
Programming the Modero X Series touch panels requires the use of the latest versions of
NetLinx Studio and TPDesign4, both available to download at www.amx.com. Refer to the
NetLinx Studio and TPDesign4 online help for information.
For additional information on the MXD-2000XL-PAN, refer to the X-Series Touch
Panels MXD/T-2000-XL-PAN & MXD/T-1900 -PAN Instruction Manual .
For detailed information on the Settings menu as well programming information and
instructions on upgrading firmware, refer to the Modero X Series Programming Guide.
Power Supply
Procedures
1) Select URL in the Mode menu.
2) Enter the Master IP/URL, Master Port Number, and
Username/Password (if required by the Master).
3) Press OK to save changes.
1) Select Listen in the Mode menu.
2) Confirm the panel's IP address is on the Master's
URL list (via NetLinx Studio).
3) Press OK to save changes.
Note: The Host Name (set on the Ethernet page), can be
used to locate the panel on the Master (particularly
useful for DHCP connections where the IP address can
change).
1) Select Auto in the Mode menu.
2) Enter the System Number and Username and
Password (if applicable).
3) Press OK to save changes.
93-5968-05
REV: J

Advertisement

loading

This manual is also suitable for:

Amx modero x mxd-2000xl-pan-pAmx modero x mxd-2000xl-pan-lFg5968-05Fg5968-11