Page 1
S E R I ES TO U C H PA N E L S MXT-2000XL-PAN 20.3" MODERO X SERIES PANORAMIC TABLETOP TOUCH PANEL MXD-2000XL-PAN-P 20.3" MODERO X SERIES PORTRAIT WALL MOUN T TOUCH PANEL MXD-2000XL-PAN-L 20.3" MODERO X SERI ES LANDSCAPE WALL MOUNT TOUCH PANEL MXT-1900L-PAN 19.
Page 2
IMPORTANT SAFETY INSTRUCTIONS READ these instructions. KEEP these instructions. HEED all warnings. FOLLOW all instructions. DO NOT use this apparatus near water. CLEAN ONLY with dry cloth. DO NOT block any ventilation openings. Install in accordance with the manufacturer's instructions. DO NOT install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Page 3
ESD WARNING To avoid ESD (Electrostatic Discharge) damage to sensitive components, make sure you are properly grounded before touching any internal materials. When working with any equipment manufactured with electronic devices, proper ESD grounding procedures must be followed to make sure people, products, and tools are as free of static charges as possible. Grounding straps, conductive smocks, and conductive work mats are specifically designed for this purpose.
Page 4
EU COMPLIANCE INFORMATION: Eligible to bear the CE mark; Conforms to European Union Low Voltage Directive 2006/95/EC; European Union EMC Directive 2004/108/EC; European Union Restriction of Hazardous Substances Recast (RoHS2) Directive 2011/65/EU; European Union WEEE (recast) Directive 2012/19/EU; European Union Radio and Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC.
Table of Contents Table of Contents Modero X Series (G4) Touch Panels ..............8 Overview ..........................8 Multi-Functional Sleep Button................... 9 Powering the Panel On/Off ........................9 Configuration and Programming ................... 10 Accessing the Settings Menu ....................... 10 Using the Settings Pages........................10 Bluetooth Support ......................
Page 6
Table of Contents MXD-430 - 4.3” X Series Panels ..............36 MXD-430 4.3" Modero X Series Wall/Flush Mount Touch Panel ........36 MXD-430 Specifications ........................36 Installing Tabletop (MXT) Panels ..............39 MXT-2000XL-PAN / MXT-1900L-PAN ................39 Connector Locations - MXT-2000XL-PAN / MXT-1900L-PAN .............. 39 MXT-1000 / MXT-700 ....................
Page 7
Panel Isn’t Appearing In The Online Tree Tab ..................71 Can’t Connect To a NetLinx Master ...................... 71 Only One Modero X Series Panel In My System Shows Up..............71 Modero X® Series Touch Panels - Installation & Hardware Reference Manual...
The distinctive appearance will complement even the most sophisticated meeting facilities and homes. Modero X Series G4 Touch Panels FIG. 1 The Modero X Series Touch Panels covered in this manual include: Modero X Series Touch Panels Name...
NOTE: The X Series panels described in this document represent a different product family than the X Series G5 touch panels. For information on X Series G5 touch panels, refer to the Modero X Series G5 Touch Panels Instruction Manual.
Settings menu, press and hold the Sleep button, and select Settings. NOTE: Unlike previous G4 touch panels, Modero X Series G4 touch panels do not have separate Setup and Protected Setup pages. All touch panel settings and functionality are now controlled through one Settings menu. The Connection & Networks and Conf iguration sections are accessible with the correct password.
Picture View By connecting a USB drive via one of the device’s USB ports, Picture View allows the Modero X Series panel to access JPEG images on that drive and display them on the touchscreen. Individual images may be accessed at any time, or the entire collection may be displayed for predetermined times.
Cleaning the Touch Overlay and Case Modero X Series touch panels come with the MXA-CLK Modero X Series Cleaning Kit (FG5968-16), which may be used to clean fingerprints and dirt from the device. This kit comes with cleaning cloths and a bottle of cleaning fluid specifically for use with the device.
MXT/D-2000XL-PAN - 20.3" X Series Panels MXT/D-2000XL-PAN - 20.3" X Series Panels MXT-2000XL-PAN (Tabletop) NFC Sensor Sleep Button USB Ports (2) Cable Slot MXT-2000XL-PAN - Front View FIG. 6 MXT-2000XL-PAN Specif ications MXT-2000XL-PAN Specif ications DIMENSIONS (HWD) 9 3/16" x 20 3/8" x 5 7/8" (235 mm x 519 mm x 150 mm) WEIGHT 12.2 lbs (5.53 Kg) POWER CONSUMPTION...
Page 14
MXT/D-2000XL-PAN - 20.3" X Series Panels MXT-2000XL-PAN Specif ications (Cont.) MEMORY • SDRAM: 512 MB • Flash: 4 GB • Maximum Project Size: 2.4 GB flash available to user COMMUNICATIONS • Ethernet: 10/100 port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP •...
MXT/D-2000XL-PAN - 20.3" X Series Panels MXT-2000XL-PAN Specif ications (Cont.) INCLUDED ACCESSORIES • Locking 2-pin Phoenix mate (41-0002-SA) • MXA-USB-C, USB Port Cover Kit, Modero X/S Series Touch Panel (FG5968-18) • HPG-10-10K, 3/4" Mini-Grommet (FG570-01) • MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) OPTIONAL ACCESSORIES •...
Page 16
MXT/D-2000XL-PAN - 20.3" X Series Panels MXD-2000XL-PAN Specif ications (Cont.) EXTERNAL POWER SUPPLY Requires one of these AMX power sources (not included): REQUIRED • PSN4.4 Power Supply, 4.4 A, 3.5 mm Phoenix, 13.5V (FG423-45) • MXA-MPL Modero X/S Series Multi Preview Live (FG5968-10) •...
Page 17
Standby: 10.6 BTU/hr INCLUDED ACCESSORIES • Locking 2-pin Phoenix mate (41-0002-SA) • MXA-USB-C, USB Port Cover Kit, Modero X Series Touch Panel (FG5968-18) • MXA-CLK, Modero X Series Cleaning Kit (FG5968-16) • Installation Template 20.3" (68-5968-01) Modero X® Series Touch Panels - Installation & Hardware Reference Manual...
Page 18
OPTIONAL ACCESSORIES • MXA-RMK-20 Modero X Series Rack Mount Kit (FG5969-60) • MXA-FMK-20 Flush Mount Kit for 20.3" Modero X Series Wall Mount Touch Panels (FG5968-68) • MXA-MP, Modero X/S Series Multi Preview (FG5968-20) • MXA-MPL Modero X/S Series Multi Preview Live (FG5968-10) •...
MXT/D-1900L-PAN - 19.4" X Series Panels MXT/D-1900L-PAN - 19.4" X Series Panels MXT-1900L-PAN (Tabletop) NFC Sensor Sleep Button USB Ports (2) Cable Slot MXT-1900L-PAN - Front View FIG. 8 MXT-1900L-PAN Specif ications MXT-1900L-PAN Specif ications DIMENSIONS (HWD) 7" x 20 3/8" x 5 5/16" (177 mm x 519 mm x 135 mm) WEIGHT 9.4 lbs (4.26 Kg) POWER CONSUMPTION...
Page 20
MXT/D-1900L-PAN - 19.4" X Series Panels MXT-1900L-PAN Specif ications (Cont.) COMMUNICATIONS • Ethernet: 10/100 port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (3) USB host 2.0, Type A ports: Firmware upgrade, touch panel file transfer, JPEG image viewer, HID peripherals, USB audio output for headsets (1) Micro-USB device port: video output from on-board camera, USB audio from on-board microphone to host device...
MXT/D-1900L-PAN - 19.4" X Series Panels MXT-1900L-PAN Specif ications (Cont.) OPTIONAL ACCESSORIES • MXA-STMK-19, Secure Table Mount Kit, 19.4" Modero X Tabletop (FG5968-65) • MXA-MP, Modero X/S Series Multi Preview (FG5968-20) • MXA-MPL, Modero X/S Series Multi Preview Live (FG5968-10) •...
Page 22
MXT/D-1900L-PAN - 19.4" X Series Panels MXD-1900L-PAN Specif ications (Cont.) CERTIFICATIONS • FCC Part 15 Class B • CE EN 55022 • CE EN 55024 • CE EN 60950-1 • IEC 60950-1 • C-Tick CISPR 22 Class B • IC •...
Page 23
Standby: 10.6 BTU/hr INCLUDED ACCESSORIES • Locking 2-pin Phoenix mate (41-0002-SA) • MXA-USB-C, USB Port Cover Kit, Modero X Series Touch Panel (FG5968-18) • MXA-CLK, Modero X Series Cleaning Kit (FG5968-16) • Wall Template 19" (68-5968-02) Modero X® Series Touch Panels - Installation & Hardware Reference Manual...
Page 24
• MXA-BT, Bluetooth USB Adapter for Modero X/S Series (FG5968-19) • MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) • MXA-USB-C, USB Port Covers for the Modero X Series Touch Panels (FG5968-18) • MXA-HST, Bluetooth Handset for Modero X/S Series Touch Panels (FG5968-17) NOTE: The MXD-1900L-PAN-P-NC (FG5968-22) and MXD-1900L-PAN-L-NC (FG5968-23) "No Comm"...
MXT/D-1000 - 10.1" X Series Panels MXT/D-1000 - 10.1" X Series Panels MXT-1000 (Tabletop) NFC Sensor Sleep Button USB Ports (2) MXT-1000 Touch Panel FIG. 10 MXT-1000 Specif ications MXT-1000 Specif ications DIMENSIONS (HWD) 6 7/8" x 9 7/8" x 4 7/8" (174 mm x 252 mm x 124 mm) WEIGHT 3.0 lbs (1.36 Kg) POWER CONSUMPTION...
Page 26
MXT/D-1000 - 10.1" X Series Panels MXT-1000 Specif ications (Cont.) COMMUNICATIONS • Ethernet: 10/100 Auto MDI-X port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (2) USB host 2.0, Type A ports (1 with limited physical access requiring right angle connection): Firmware upgrade, touch panel file transfer, JPEG image viewer, HID peripherals, USB audio output for headsets (1) Micro-USB device port: video output from on-board camera (landscape touch panel only), USB...
• MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) • NXA-ENET8-2POE, Gigabit PoE Ethernet Switch (FG2178-63) • MXA-USB-C, USB Port Covers for the Modero X Series Touch Panels (FG5968-18) • MXA-HST, Bluetooth Handset for Modero X/S Series Touch Panels (FG5968-17) NOTE: The MXT-1000-NC (FG5968-24) "No Comm" touch panel does not have camera, microphone, NFC or Bluetooth capability;...
Page 28
MXT/D-1000 - 10.1" X Series Panels MXD-1000 Specif ications (Cont.) CERTIFICATIONS • UL 60950-1 • FCC Part 15 Class B • C-Tick CISPR 22 Class B • CE EN 55022, EN 55024 and EN 60950-1 • IEC 60950-1 • IC •...
Page 29
On: 21.3 BTU/hr Standby: 10.6 BTU/hr INCLUDED ACCESSORIES • MXA-USB-C, USB Port Cover Kit, Modero X Series Touch Panel (FG5968-18) • MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) • Installation Template, 10" Modero X Series (68-5968-03) Modero X® Series Touch Panels - Installation & Hardware Reference Manual...
• MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) • NXA-ENET8-2POE, Gigabit PoE Ethernet Switch (FG2178-63) • MXA-USB-C, USB Port Cover Kit, Modero X Series Touch Panel (FG5968-18) • MXA-HST, Bluetooth Handset for Modero X Series Touch Panels (FG5968-17) NOTE: The MXD-1000-P-NC (FG5968-25) and MXD-1000-L-NC (FG5968-26) "No Comm" touch panels do not have camera, microphone, NFC or Bluetooth capability;...
MXT/D-700 - 7" X Series Panels MXT/D-700 - 7" X Series Panels MXT-700 (Tabletop) NFC Sensor Sleep Button USB Ports (2) MXT-700 touch panel FIG. 12 MXT-700 Specif ications MXT-700 Specif ications DIMENSIONS (HWD) 5" x 7 5/16" x 4 1/8" (126 mm x 187 mm x 105 mm) WEIGHT 1.8 lbs (0.82 Kg) POWER CONSUMPTION...
Page 32
MXT/D-700 - 7" X Series Panels MXT-700 Specif ications (Cont.) COMMUNICATIONS • Ethernet: 10/100 Auto MDI-X port, RJ-45 connector. Supported IP and IP-based protocols: UCP, TCP, ICMP, ICSP, IGMP, DHCP, Telnet, FTP, DNS, RFB (for VNC), HTTP • USB: (2) USB host 2.0, Type A ports (1 with limited physical access requiring right angle connection): Firmware upgrade, touch panel file transfer, JPEG image viewer, HID peripherals, USB audio output for headsets •...
MXT/D-700 - 7" X Series Panels NOTE: The MXT-700-NC (FG5968-27) "No Comm" touch panel does not have camera, microphone, NFC or Bluetooth capability; otherwise it has all of the functionality of the MXT-700. Touch Panel Aspect Ratio While the touch panel screen physical dimensions fall between 16:9 and 16:10, any incoming video stream can be scaled to 16:9 if needed.
Page 34
MXT/D-700 - 7" X Series Panels MXD-700 Specif ications (Cont.) TOUCH SCREEN DISPLAY • Display Type: TFT Active Matrix Color LCD with Fringe Field Switching (FFS) - Wide Viewing Angle Technology • Display Size (WH) Landscape: 7.3" x 4.8" (186 mm x 122 mm), 8.8" (222 mm) diagonal Portrait: 4.8"...
• Power ("Heat") Dissipation: On: 18.5 BTU/hr Standby: 10.6 BTU/hr INCLUDED ACCESSORIES • MXA-USB-C, USB Port Cover Kit, Modero X Series Touch Panel (FG5968-18) • MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) • Installation Template, 7" Modero X Series (68-5968-04) OPTIONAL ACCESSORIES •...
MXD-430 - 4.3” X Series Panels MXD-430 - 4.3” X Series Panels MXD-430 4.3" Modero X Series Wall/Flush Mount Touch Panel Left LED Right LED Sleep Button RJ45 Port Port Sensor front rear MXD-430 FIG. 14 MXD-430 Specif ications MXD-430 Specif ications DIMENSIONS (HWD) Portrait: 4 7/8"...
Page 37
On: 22.2 BTU/hr Standby: 14.3 BTU/hr INCLUDED ACCESSORIES • MXA-USB-C, USB Port Cover Kit, Modero X Series Touch Panel (FG5968-18) • MXA-CLK, Modero X/S Series Cleaning Kit (FG5968-16) • Installation Template, 4.3" Modero X Series (68-5968-05) Modero X® Series Touch Panels - Installation & Hardware Reference Manual...
Page 38
MXD-430 - 4.3” X Series Panels MXD-430 Specif ications (Cont.) OPTIONAL ACCESSORIES • MXA-FMK-43, Flush Mount Kit for 4.3" Modero X Series Wall Mount Touch Panel (FG5968-72) • MXA-MP, Modero X/S Series Multi Preview (FG5968-20) • MXA-MPL, Modero X/S Series Multi Preview Live (FG5968-10) •...
Installing Tabletop (MXT) Panels Installing Tabletop (MXT) Panels MXT-2000XL-PAN / MXT-1900L-PAN Detailed specifications drawings for the MXT-2000XL-PAN MXT-1900L-PAN are available to download from www.amx.com. Connector Locations - MXT-2000XL-PAN / MXT-1900L-PAN Two Type A USB ports are located on the rear right corner of the panel (FIG. 15). USB peripherals (i.e. mouse, keyboard) may be connected to either of the two USB ports on the rear of the device.
Installing Tabletop (MXT) Panels MXT-1000 / MXT-700 Detailed specifications drawings for the MXT-1000 MXT-700 are available to download from www.amx.com. Connector Locations - MXT-1000/MXT-700 Two Type A USB ports are located on the rear right corner of the panel (FIG. 18). USB peripherals (i.e. mouse, keyboard) may be connected to either of the two USB ports on the rear of the device.
Page 41
Installing Tabletop (MXT) Panels Ethernet Cable Clamp Connector Bottom of the MXT-700/1000 FIG. 20 NOTE: The minimum diameter hole through which the Ethernet cable may pass is 0.50" (1.27 cm). To disconnect and reconnect the Ethernet cable on the MXT-700 and MXT-1000 to allow use of a hole smaller than 1.00” in diameter: On a soft surface, turn the MXT-1000 face-down to access the bottom of the device.
Installing Wall-Mount (MXD) Panels Installing Wall-Mount (MXD) Panels A Note About Wall and Rack Installation Some products are installed in areas of differing temperature and cooling methodologies. These include products installed in walls, racks, cabinets, etc. Those areas may have different temperatures and/or cooling approaches that must be taken into consideration to maintain the product within the specified operating temperature.
Installing Wall-Mount (MXD) Panels Installation Recommendations During any installation, a lack of ventilation may produce conditions that may adversely affect the device’s operation. In these circumstances, special care must be made to make sure that temperatures within enclosed areas do not exceed the device’s maximum rated temperature.
Installing Wall-Mount (MXD) Panels NOTE: When installing the Backbox, make sure that the assembly is in the correct position and in the correct place. Once the locking tabs are extended and locked into place, removing the Backbox may be diff icult without having access to the back of the wall or causing damage to the wall.
Installing Wall-Mount (MXD) Panels MXD-1900L-PAN Dimensions FIG. 26 provides dimensions for the MXD-1900L-PAN: Notes: Dimensions in parenthesis are in millimeters Additional detailed installation and product drawings are available to view/download at www.amx.com MXD-1900L-PAN - Dimensions FIG. 26 NOTE: In order to ensure a stable installation, the thickness of the wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches (2.22cm).
Installing Wall-Mount (MXD) Panels Installing the Backbox MXD-2000XL-PAN Installation Dimensions FIG. 27 and FIG. 28 provide installation dimensions for the MXD-2000XL-PAN: MXD-2000XL-PAN-L Installation Dimensions (front view) FIG. 27 Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation.
Installing Wall-Mount (MXD) Panels MXD-1900L-PAN Installation Dimensions FIG. 29 and FIG. 30 provide installation dimensions for the MXD-1900L-PAN: MXD-1900L-PAN-L Installation Dimensions (front view) FIG. 29 Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation.
Page 48
Installing Wall-Mount (MXD) Panels Cables Routed to Wall Opening Wall 4X Installation Clamp for Wall Thickness .37 [12.01] to .98 [25.0] 8X Knock Outs Mounting screws Remove For Cable Routing As Needed placement (optional) Note: Additional detailed installation and product drawings are available to view/download at www.amx.com MXD-1900L-PAN Backbox installation (Landscape) FIG.
Page 49
Installing Wall-Mount (MXD) Panels 13.5V Power Port Ethernet 10/100 Port Type A USB Port (limited access) MXD-2000XL-PAN / MXD-1900L-PAN - rear connectors FIG. 32 NOTE: Refer to the Power via 13.5V section on page 50 for details on wiring a power connection. Test the incoming wiring by attaching the panel connections to their terminal locations and applying power.
Installing Wall-Mount (MXD) Panels NOTE: When installing the panel, do NOT press on or near the center of the panel. Too much stress at the center may damage the touch screen surface. When installing the panel, pressure should be applied toward the ends of the panel ONLY. 10.
Installing Wall-Mount (MXD) Panels NOTE: Always pull on the frame of the touch panel. NEVER pull on the glass edge. When the first side is free, repeat the process with the other. With the edge of the touch panel free, carefully lift up and out (Landscape) or to the left and out (Portrait) to remove the touch panel from the Backbox.
Installing Wall-Mount (MXD) Panels NOTE: When installing the Backbox, make sure that the assembly is in the correct position and in the correct place. Once the locking tabs are extended and locked into place, removing the Backbox may be diff icult without having access to the back of the wall or causing damage to the wall.
Installing Wall-Mount (MXD) Panels MXD-700 Dimensions FIG. 38 provides dimensions for the MXD-700: Notes: Dimensions in parenthesis are in millimeters Additional detailed installation and product drawings are available to view/download at www.amx.com MXD-700 - Dimensions FIG. 39 NOTE: In order to ensure a stable installation, the thickness of the wall material must be a minimum of .50 inches (1.27cm) and a maximum of .875 inches (2.22cm).
Installing Wall-Mount (MXD) Panels Installing the Backbox MXD-1000 Installation Dimensions FIG. 41 and FIG. 42 provide installation dimensions for the MXD-1000: MXD-1000 Installation Dimensions (front view) FIG. 40 Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation.
Installing Wall-Mount (MXD) Panels MXD-700 Installation Dimensions FIG. 42 and FIG. 43 provide installation dimensions for the MXD-700: MXD-700-L Installation Dimensions (front view) FIG. 42 Notes: - Dimensions in parenthesis are in millimeters. - These drawings show a Landscape panel. The dimensions are the same for Portrait panels, except for the vertical orientation.
Page 56
Installing Wall-Mount (MXD) Panels Leave enough slack in the wiring to accommodate any re-positioning of the panel. FIG. 44 shows the MXD-1000 Backbox installation: 4X Installation Clamp for Wall Thickness .31 [12.0] to .98 [.25.0] 4X Knock-Outs Remove for Cable Routing as Needed #4 Screws MXD-1000 Backbox Installation (Landscape)
Installing Wall-Mount (MXD) Panels Push the Backbox into the mounting surface. Insure that the locking tabs lie flush against the Backbox and that the Backbox goes freely into the opening. Extend the locking tabs on the sides of the Backbox by tightening the screws inside the box until snug. NOTE: The maximum recommended torque to screw in the locking tabs on the plastic Backbox is 5 IN-LB [56 N-CM].
Installing Wall-Mount (MXD) Panels Ethernet Cable Installation and Modif ication In tabletop installations where concealing the Ethernet cable is desired, a hole at least 1.00” (2.54 cm) in diameter is required in the surface to allow passage of the female RJ45 connector (FIG. 47). If using a smaller hole is unavoidable, you will need to disconnect the Ethernet cable (ECA5968-05) from the device, to feed the male end of the cable through.
Installing Wall-Mount (MXD) Panels On the bottom (Landscape) or right side (Portrait) of the MXD-1000, locate the seventh and eight ventilation holes from each edge, on the row closest to the Backbox (FIG. 49):. Panel (surface) Access holes Access holes #7, #8 #8, #7 Bottom View (Landscape) or Right-Side View (Portrait) of the MXD-1000 showing access holes in molding...
Installing Wall-Mount (MXD) Panels Panel (surface) Access hole Access hole Bottom View (Landscape) or Right-Side View (Portrait) of the MXD-700 showing access holes in molding FIG. 51 With a stout, strong point (a push pin or straightened paper-clip, for example), carefully press into the access holes in either end of the molding until the snap is disconnected.
Page 61
Installing Wall-Mount (MXD) Panels NOTE: When installing the backbox, make sure that the assembly is in the correct position and in the correct place. Once the locking tabs are extended and locked into place, removing the backbox may be diff icult without having access to the back of the wall or causing damage to the wall.
Installing Wall-Mount (MXD) Panels Installing the Backbox FIG. 54 provides installation dimensions for the MXD-430: Notes: Dimensions in parenthesis are in millimeters Additional detailed installation and product drawings are available to view/download at www.amx.com MXD-430 - Installation Dimensions (front view) FIG.
Page 63
Installing Wall-Mount (MXD) Panels MXD-430 Backbox Installation - Solid Surface FIG. 55 FIG. 56 provides an illustration of the MXD-430 mounting into a drywall surface: MXD-430 Backbox Installation - Drywall Surface FIG. 56 Leave enough slack in the wiring to accommodate any re-positioning of the panel. Remove the knockout on the bottom of the Backbox (FIG.
Page 64
Installing Wall-Mount (MXD) Panels Extend the locking tabs on the sides of the Backbox by tightening the screws inside the box until snug. NOTE: The maximum recommended torque to screw in the locking tabs on the plastic Backbox is 5 IN-LB [56 N-CM]. Applying excessive torque while tightening the tab screws, such as with powered screwdrivers, can strip out the locking tabs or damage the Backbox.
Installing Wall-Mount (MXD) Panels Snap Backbox Mounting Surface Latch Hooks Installing the MXD-430 FIG. 58 NOTE: If you see a gap between the panel and the Backbox or feel any binding while locking down the panel, stop immediately and verify that no cables or other items are in the way. Do not force the panel into position, as this can cause damage to the touch screen or the panel electronics.
Page 66
Installing Wall-Mount (MXD) Panels Molding MXD-430 Molding (highlighted in blue) FIG. 59 On the top of the MXD-430, locate the seventh ventilation holes from each edge, on the row closest to the glass (FIG. 60):. Access hole Access hole #7 #7 Panel (surface) Top View of the MXD-430 showing access holes in molding FIG.
Upgrading Firmware Upgrading Firmware Overview Programming X Series G4 touch panels require the use of NetLinx Studio and TPDesign4, both available from www.amx.com. Downloading Firmware Updates From www.amx.com Before attempting to upgrade the firmware, you must have the appropriate Kit file for your touch panel: NOTE: All X Series touch panels share the same f irmware.
Upgrading Firmware Previous Firmware installation confirmation dialog FIG. 64 If you choose Yes, the device will retrieve the files and then reboot. Returning to Factory Default Firmware X Series panels allow the option to return the device to its original factory default firmware, which may be necessary in certain situations.
Page 70
Upgrading Firmware NetLinx Studio - Send to NetLinx Device dialog FIG. 66 NOTE: If for any reason your Kit f ile transfer should fail, continue to retry the transfer until you are successful. DO NOT reboot the Master, or change connections until the transfer is complete. Failure to complete this operation successfully may result in a factory repair of the Master.
Only One Modero X Series Panel In My System Shows Up Symptom: I have more than one Modero X Series panel connected to my System Master and only one shows up. Multiple NetLinx Compatible devices can be associated for use with a single Master. If the user does not assign a device number, one will be assigned automatically to the panel.
Need help?
Do you have a question about the MODERO X Series and is the answer not in the manual?
Questions and answers