Gree GWH09QB-K3DNC2G Service Manual page 67

Hide thumbs Also See for GWH09QB-K3DNC2G:
Table of Contents

Advertisement

Display Method of Indoor Unit
Malfunction
NO.
Dual-8
Name
Code
Display
Internal motor
34
(fan motor) do
H6
not operate
Desynchro-
35
nizing of
H7
compressor
PFC
36
HC
protection
Outdoor DC
37
fan motor
L3
malfunction
power
38
L9
protection
Indoor unit
and outdoor
39
LP
unit doesnt
match
Failure start-
40
LC
up
Normal
41
communica-
tion
42
Defrosting
64
Display Method of Outdoor
Indicator has 3 kinds of
Indicator Display (during
display status and during
blinking, ON 0.5s and OFF
blinking, ON 0.5s and OFF
0.5s)
0.5s
Operation
Cool
Heating
Yellow
Indicator
Indicator
Indicator
Indicator
OFF 3S
and blink
14 times
OFF 3S
and blink
9 times
OFF 3S
and blink
16 times
OFF 3S
and blink
once
OFF 3S
(during
and blink
blinking,
twice
ON 10s
and OFF
0.5s)
Unit
A/C status
Red
Green
Indicator
Indicator
Internal fan motor, external fan
motor, compressor and electric
heater stop operation,guide
louver stops at present
location.
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
operation.
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
operation.
OFF 3S
Outdoor DC fan motor
and
malfunction lead to compressor
blink
stop operation,
14 times
compressor stop operation and
Outdoor fan motor will stop
30s latter , 3 minutes latter
fan motor and compressor will
restart
compressor and Outdoor fan
motor cant work
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
operation.
contino-
usly
Defrosting will occur in heating
mode. Compressor will operate
while indoor fan will stop
operation.
Service Manual
Possible Causes
1. Bad contact of DC motor
feedback terminal.
2. Bad contact of DC motor
control end.
3. Fan motor is stalling.
4. Motor malfunction.
5. Malfunction of mainboard rev
detecting circuit.
Refer to the malfunction
analysis (IPM protection, loss
of synchronism protection and
overcurrent protection of phase
current for compressor.
Refer to the malfunction analysis
DC fan motor malfunction or
system blocked or the connector
loosed
To protect the electronical
components when detect high
power
Indoor unit and outdoor unit doesnt
match
Refer to the malfunction analysis
Its the normal state
Installation and Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents