Proper Installation - Mitsubishi Heavy Industries SKM20ZSP-S User Manual

Hide thumbs Also See for SKM20ZSP-S:
Table of Contents

Advertisement

Cooling/heating is affected by an air fi lter clogged up with dust etc., and the operation noise becomes louder. It
NOTE
may also use extra electricity. Please clean the air fi lter at recommendation intervals.
At the end of the season
Perform the fan operation for a half day.
1
Dry the inside of the unit.
Cooling season only.
Stop the unit and turn off the power source.
2
The unit consumes approx. 2W even when the unit is not op-
erating. Turning off the power source will help saving energy
consumption and cost.
Clean and reinstall the air fi lter.
3
Clean both the indoor and outdoor units.
4
Remove batteries from the remote control.
5

Proper installation

Suitable installation position
• Do not put any obstruction in front of the indoor unit, preventing proper ventilation and functioning.
• Do not install the unit in any of the following places:
• Where there is a danger of leaking fl ammable gases.
• Where there is substantial splashing of oil.
• Malfunctioning due to corrosion may occur if the unit is installed in a spa where sulfi de gases are generated, or in a seaside resort
exposed to sea breezes. Contact your dealer.
• The air-conditioner and remote control must be at least 1 metre away from a TV set or radio.
• Drain the dehumidifi ed liquid from the indoor unit into a spot that drains well.
Pay attention to operating noises!
• When you install the unit, take care to choose a place that can comfortably stand the weight of the unit and does not increase the operating noise
or vibration. If vibration is transmitted through the house, fi x the unit with the aid of vibration-proof pads between the unit and the fi ttings.
• Select a place where cold or hot air, operation noises from the indoor and outdoor units do not cause any inconvenience to your neighbours.
• Do not leave any obstacles near the outlet and inlet of the outdoor unit. This may cause malfunctioning and increased operating noise.
• If you hear an irregular noise during operation, contact your dealer.
Depending on operating environment, the inside of the air-conditioner may become dirty after a few year operations. This will reduce
performance. In addition to normal cleaning, we would recommend inspection and maintenance. (This may lead the air-conditioner to
having a longer life without any trouble.)
• Contact your dealer, or any distributor, for inspection and maintenance. (There will be a charge for this service).
• We would recommend inspection and maintenance to be carried out during the off-season.
• If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because
special purpose tools are required.
At the beginning of the season
Make sure that there are no obstacles block-
1
ing the airfl ow around the air intake and outlet
openings of the indoor and outdoor units.
Check if there is no corrosion or rust on the
2
base frame of the outdoor unit.
Ensure that the earth wiring is not snapped nor
3
disconnected.
Ensure that the air fi lter are clean.
4
Turn on the power source.
5
Insert batteries in the remote control.
6
Inspection and maintenance