(where expected) "LL" The water level in the tank is not suffi-
cient (the pumps cannot be activated).
- Add water to the hot tub until the message disappears.
"FLt" filtering is active (please see the relevant chapter)
- You do not need to take any action.
"ICE" the "Smart winter" function is active (anti-freeze, please
see relevant chapter)
- You do not need to take any action.
"CO" the spotlight control system does not work
- Contact an authorised Jacuzzi® service centre.
"FLO" The flow switch does not detect the water flow (heating
cannot be turned on).
- check that dipswitch no. 8 is set to OFF (see the "Electrical con-
nections and safety" chapter).
- Flow switch may be faulty; contact an authorised Jacuzzi® ser-
vice centre.
"FLC" The flow switch shows the water flow when the filtering
pump is off
- Flow switch may be faulty; contact an authorised Jacuzzi® ser-
vice centre.
"Er" Water temperature beyond the range managed by the sys-
tem or faulty temperature probe.
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 45 °C (111 °F) or it
has dropped below 5 °C (41 °F). It is no t possible to turn any func-
tion on.
- If present, remove the cover from the hot tub, so as to facilitate
cooling of the water.
- Add cold water to the hot tub if sunlight causes an excessive
increase in temperature.
When the temperature is within the allowed range, the pumps
can be activated again; if this does not happen, the fault could
be caused by a problem with the temperature probe: turn off
the power and contact an authorised Jacuzzi® Service Centre.
"HI" Excessive water temperature.
DO NOT ENTER THE WATER
The water temperature has reached or exceeded 42 °C (107.6 °F). It
is not possible to turn any function on.
- If present, remove the cover from the hot tub.
- Add cold water to the hot tub if sunlight causes an excessive
increase in temperature.
When the temperature has dropped to below 40°C (109°F), the
pumps can be activated again; if this does not happen, discon-
nect the power supply and contact an authorised Jacuzzi® ser-
vice centre.
For all special maintenance work, we recommend contacting
an authorised Jacuzzi® service centre, providing the following
information:
- model;
- purchase date;
- serial number (shown on the warranty certificate).
Model _______________________________
Purchase date __________________________
Serial number __________________________