for 4 Channels HA2B5-S / HA3B3-S
hivolt.de GmbH & Co. KG
Oehleckerring 40
D-22419 Hamburg
HA2B5-S
High Voltage Amplifier ±2000V
HA3B3-S
High Voltage Amplifier ±3000V
HAR42-4
Operating Manual
Germany
 +49 40 537122-0
 +49 40 537122-99
info@hivolt.de
1
www.hivolt.de

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HA2B5-S and is the answer not in the manual?

Questions and answers

Summary of Contents for hivolt HA2B5-S

  • Page 1 HA2B5-S High Voltage Amplifier ±2000V HA3B3-S High Voltage Amplifier ±3000V HAR42-4 High Voltage Amplifier Mainframe for 4 Channels HA2B5-S / HA3B3-S Operating Manual hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany  +49 40 537122-0  +49 40 537122-99 info@hivolt.de...
  • Page 2: Table Of Contents

    Grounding 5.10 DIP Switch S1 5.11 Internal Connectors OPERATION / MAINTENANCE Troubleshooting Maintenance Cleaning DECLARATION OF CONFORMITY hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany  +49 40 537122-0  +49 40 537122-99 info@hivolt.de www.hivolt.de ∙ ∙ ∙...
  • Page 3: Warnings

     Fuses have to be replaced by types as rated on the nameplate on the rear of the unit.  Personal safety must be given the highest priority! hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany  +49 40 537122-0 ...
  • Page 4 Sollte ein Ersatz der Netzsicherungen erforderlich sein, so ist sicherzustellen, dass nur  Sicherungen der angegebenen Nennstromstärke und Nennspannung als Ersatz verwendet werden. Der Personensicherheit ist höchste Priorität einzuräumen! hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany  +49 40 537122-0 ...
  • Page 5: Overview

    For HA2B5-S output voltages of -2000V to +2000V at load currents of up to ±5mA and >7mA provided. The signal gain is 200, the input voltage range is -10V…+10V.
  • Page 6: Control Voltage Input

    (180° phase shift in respect to amplifier 1). This mode can be used e. g. to differentially drive two deflection plates or to drive a floating load with up to 8000V hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany ...
  • Page 7: Disable

    Achievable slew rate: SR = I [V/s]. If the average positive or negative output current exceeds 5mA (HA2B5-S) or 3mA (HA3B3-S) the amplifier shuts down with Overload. If the maximum slew rate is exceeded, distortions occur in the output signals. In principle, the amplifier should thus only be controlled by input signals that satisfy the achievable slew rate for a given load.
  • Page 8: Protection

    The device must be disconnected from the power supply before carrying out any operations on the test setup or before touching the output terminals. hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany  +49 40 537122-0  +49 40 537122-99 info@hivolt.de...
  • Page 9: Technical Data

    - Signal ground and high voltage ground are connected to chassis ground / protective earth and the earth connector (M4 nut). - The appliance conforms to protection category I. It must only be used on mains power sockets with a ground connection. Amplifier modules HA2B5-S / HA3B3-S Parameter Conditions Supply voltage, V ±10%...
  • Page 10: Frequency Response Of Current Monitor

    - Operation - Storage and Transportation - Depending on the ambient temperature, modulation amplitude and load capacitance, the maximum output power may need to be derated. hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany  +49 40 537122-0 ...
  • Page 11: Mechanical Specifications

    Mechanical Specifications Mainframe HAR42-4 Parameter Unit Depth overall Depth case Width overall Width case Height Weight without amplifier modules Amplifier module HA2B5-S / HA3B3-S Parameter Unit Depth overall Depth module Width Height Weight 0.51 hivolt.de GmbH & Co. KG Oehleckerring 40...
  • Page 12: Operation

    This symbol on the output terminals warns of the risk of electric shock. Temperature Compensation To avoid condensation within the device, it should be allowed to reach the room temperature. Please unpack the product at least two hours prior to power-up. hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany ...
  • Page 13: Power Supply

    15. The Interlock LEDs will light up continuously. 16. Press the SDN Reset push button. 17. The interlock status remains unchanged and the high voltage cannot be switched on. 18. Turn off the supply voltage. hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany ...
  • Page 14: Connector X1 Interlock

    Overload, Overtemperature) is no longer pending. It is recommended to operate the unit with shutdown latches enabled and actively reset any shutdown condition via the SDN Reset push button or the SDN signal on X1. hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany ...
  • Page 15: Internal Connectors

    5.11 Internal Connectors Internal connector X1 of HA2B5-S / HA3B3-S plug-in modules (DIN41612, Type F) Pins Signal Function n.c. n.c. n.c. n.c. D10 B10 Z10 n.c. D12 B12 Z12 GND D14 B14 Z14 n.c. D16 B16 Z16 n.c. HVON_BP HV enable input; used for interlock or general high voltage ON;...
  • Page 16: Operation / Maintenance

    Caution: disconnect the unit from the power supply before removing any modules or opening any covers. Further regular maintenance is not required. Cleaning If necessary, wipe the device with a slightly damp cloth. Do not use abrasive detergents or solvents. hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg Germany  +49 40 537122-0 ...
  • Page 17 © hivolt.de GmbH&Co. KG, Hamburg, Germany As of 03/2021 Document History: Version Date Name Changes 2019-09-03 Created 2020-10-19 extended description of internal connector X1 2021-03-09 HA3B3-S added 2021-07-16 pin-assignment X1 IOAV_BP, VOAV_BP corrected hivolt.de GmbH & Co. KG Oehleckerring 40...
  • Page 18: Declaration Of Conformity

    EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements Classification: Group 1, Class B Manufacturer: hivolt.de GmbH & Co. KG Oehleckerring 40 D-22419 Hamburg 2021-03-09 Wulf Müller Managing Director hivolt.de GmbH & Co. KG...