Rebuilding Data On A Replacement Disk Drive Using Linux; Fan - IBM 5786 Removal And Replacement Procedures

Table of Contents

Advertisement

To add the disk drive as a resource using Linux, do the following steps:
1. From the IBM Power RAID Configuration Utility display, select Work with disk unit recovery. Press
Enter.
2. From the Work with Disk Unit Recovery display, select Concurrent add device. Press Enter.
A Concurrent Device Add displays.
3. Type select 1 next to the location from which you removed the disk drive.
The Verify Device Concurrent Add display is shown.
4. Press Enter on the Verify Device Concurrent Add display. The Complete Device Concurrent Add
display is shown.
5. Press Enter on the Complete Device Concurrent Add display to indicate that the disk drive is
installed.
6. Rebuild the data on the replacement disk drive. For instructions, go to Rebuild data on a replacement
disk drive by using Linux.
7. Go to Verify a repair. This completes this procedure.

Rebuilding data on a replacement disk drive using Linux

Use this procedure to rebuild data on the replacement disk drive.
To rebuild data on the replacement disk drive, complete the steps below.
For an unprotected disk drive
If the disk drive you are replacing is in a RAID Level 0 disk array or in a failed RAID Level 5 or RAID
Level 10 disk array, perform these tasks:
1. Re-create the disk array.
2. Re-create the file systems on the disk array.
3. Copy the data back to the restored disk array from your backup media.
For information on these tasks, see the PCI-X SCSI RAID Controller Reference Guide for Linux. This guide is
available from the SCSI PCI Adapters Web page at http://publib.boulder.ibm.com/infocenter/pseries/
v5r3/index.jsp?topic=/com.ibm.pseries.doc/hardware_docs/scsipciadapters.htm.
For a disk drive in a RAID Level 5 or RAID Level 10 disk array, select the appropriate procedure:

Fan

Use this procedure to service the fan.
You can service the fan concurrently (powered on) or non-concurrently (powered off). To service the fan
concurrently, go to step 1, otherwise go to step 2.
1.
The component will be serviced concurrently. Power should not be removed from the unit containing the FRU in the
location field above during this procedure. Go to step 3.
2.
The failing component will not be replaced concurrently. Power should be removed from the enclosure containing the
FRU in the location field above. If this enclosure is powered on, power it off now. Do not apply power to the
enclosure until directed to do so in this procedure.
3.
5786, 5787, 7031-D24, and 7031-T24 removal and replacement procedures
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

57877031-d247031-t24

Table of Contents