J. Operation During A Power Outage (IPI
Plus)
The Intellifi re™ Plus intermittent pilot ignition system
comes with a battery backup system that enables the
system to operate in a power outage. The system offers
seamless transition from household AC power to battery
backup. A factory-installed battery pack is located in the
control cavity of the appliance. See Figure 3.5. Battery
longevity and performance will be affected by long term
exposure to the service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries
should not be used as a primary long-term power source.
To Operate Fireplace Using Battery Power (DC):
1. Access the control cavity of the appliance. See Figure
3.5 for location. The decorative front or door may
need to be removed.
2. Locate the battery tray and insert four AA cell batteries.
Battery polarity must be correct or module damage will
occur. A complete wiring diagram is included in the
Electrical section of the appliance Installation Manual.
3. Turn the appliance on according to the instructions for
the appropriate type of control:
CONTROL CAVITY
VALVE
3.5 Control Cavity Location
Majestic • DBDV36PLATIN, DBDV36PLATIL, DBDV42PLATIN, DBDV42PLATIL Owner's Manual • 2454-981 Rev. C • 3/17
Standard Wall Switch:
Toggle the switch as you would under normal
circumstances.
Wireless Remote:
Remote receiver is integrated into the ignition module
Use the remote to turn the appliance on.
• To preserve battery life, do not use the HI/LO fl ame or
THERMOSTAT options.
Ignition Module:
Locate the ignition module in the control cavity.
Slide the ON/REMOTE/OFF switch to the ON position.
NOTICE: Some functionality will be lost when using battery
backup including remote control, fan, lights, or any other
auxiliary functions that require household 110-120 VAC
power.
To Return to Operation Using Electrical (AC) Power
Standard Wall Switch:
Toggle the switch to OFF and remove the batteries
from the battery tray. Replace door or decorative front
on appliance.
Multifunctional Wired Wall Switch Control System:
Slide the switch to the OFF position. Remove the
batteries from the battery tray.
decorative front on appliance.
Wireless Remote:
Slide the ON/REMOTE/OFF switch to the REMOTE
position. Remove the batteries from the battery tray.
Replace door or decorative front on appliance.