Federal EIMSS60 Installation & Operation Manual page 55

Table of Contents

Advertisement

Remote IMSS60R BEFORE 5/23/12
OPTIONAL CONDENSATE
HEATER PAN
R(23)
B(22)
NO
G(24)
C
NC
B
R
SHELF LAMP
R
BL
B
R
SHELF LAMP
BL
R
R
B
SHELF LAMP
R
BL
B
TOP LAMP
R
DEFROST PROBE PB2
TEMP PROBE PB1
8
1 2 3 4 5 6 7
RIBBON
CABLE
DISPLAY
B(5)
208-240V / 60Hz / 1PH
R(2)
L2
B(1)
L1
N
POWER SWITCH
IMSS E3265
TOP LAMP
B/BL
B/BL
B
TOP LAMP
B
B/BL
B/BL
SHELF LAMP
B
B
B/BL
B/BL
SHELF LAMP
B
B
B/BL
SHELF LAMP
B
Y(6)
TERM BLOCK
TURN FULL
TURN FULL
CLOCK WISE
CLOCK WISE
9
10
11
TERM BLOCK L2
R(12)
B(13)
TERM BLOCK L1
R(4)
B(3)
91-19454 1/2/12 IMSS60R & ECSS60R
B
B/BL
B/BL
B
B
R
ECSS ONLY
B/BL
B
B
R
B
R
B/BL
B/BL
BL
B
B
R
B
R
B/BL
B/BL
R
BL
B
B
B
R
B/BL
B/BL
B
R
BL
B
Y(9)
Y(10)
1
4
R(11)
2
3
BASE FAN OPTIONAL
R(20)
R(23)
B(22)
G(24)
R(14)
EVAPORATOR FANS
RIB
RIB
R
BRW
POWER SUPPLY
B
BL
COLOR CODE
B = BLACK
BL = BLUE
W = WHITE
Y = YELLOW
G = GREEN
R = RED
BRW = BROWN
B
BRW
B/BL
POWER SUPPLY
B
R
G(25)
G
JUMP R & Y
B
BL
REFRIGERATION
SOLENOID
BRW
CONDENSATE
BL
PUMP
G
NO
C
NC
R(15)
LIGHT
SWITCH
R(15)
B(16)
BL
- 55 -

Advertisement

Table of Contents
loading

Table of Contents