Sharp R-340DK Service Manual page 26

Table of Contents

Advertisement

R- 340DK
R-340DW
Pin No.
Signal
74
LWR
OUT
75-76
MD0-MD1
77
MD2
78
Avcc
79
Vref
80
AN0
81
AN1
82
AN2
83
AN3
84
AN4
85
AN5
86
AN6
87
DA1
OUT
88
Avss
89
IRQ0
90-91
P81-P82
OUT
92
CS1
OUT
93
CS0
OUT
94
Vss
95-99
PA0-PA4
OUT
100
PA5
OUT
I/O
Terminal not used.
IN
Connected to VCC.
IN
Connected to GND.
IN
A/D converter power source voltage : +5V.
The power source voltage to drive the A/D converter. Connected to VCC.
IN
A/D converter power source voltage : +5V.
The power source voltage to drive the A/D converter. Connected to VCC.
IN
Terminal to judge whether the model has the sensor cooking function or not.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to judge whether the model has the sensor cooking function or not.
IN
Input terminal to judge the model.
The signal out of P40 will be input into AN1 through G15 line on key matrix. The LSI will
judge the model by this signal.
IN
Terminal to change cooking input according to the model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
IN
Connected to VCC.
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (+5V). Door open "L" level signal (GND).
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
The signal for the power source to drive the LCD is output to IC3.
IN
A/D converter power source voltage : GND(0V).
The power source voltage to drive the A/D converter. Connected to GND.
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
Terminal not used.
Chip select signal is output to CS terminal of IC5.
Chip select signal is output to CE terminal of IC2.
IN
Power source voltage : GND (0V).
The power source voltage to drive the LSI is input to Vss terminal.
Used for initial balancing of the bridge circuit (absolute humidity sensor).
Clock signal is output to IC5.
Description
24
H : +5V
L : GND
16.7 msec.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R-340dw

Table of Contents