Outdoor Fan Motor Control - Toshiba RAS-25PKVSG-ND Service Manual

Hide thumbs Also See for RAS-25PKVSG-ND:
Table of Contents

Advertisement

Item
3. Outdoor fan
The blowing air volume at the outdoor unit side is controlled.
motor control
Receiving the operation command from the controller of
indoor unit, the controller of outdoor unit controls fan speed.
* For the fan motor, a DC motor with non-stage variable
speed system is used. However, it is limited to 8 stages for
reasons of controlling.
Air conditioner ON
(Remote controller)
Indoor unit controller
1) Outdoor unit
operation command
(Outdoor fan control)
2) Fan speed ≥ 400
when the motor stopped.
Fan motor ON
3) Fan lock
4) Motor operates as shown in the table below.
Compressor speed
RAS-25PAVSG-ND
(Hz)
RAS-35PAVSG-ND
Fan tap
To ≥ 38°C
To ≥ 28°C
To ≥ 15°C
To
To ≥ 5.5°C
To ≥ 0°C
To ≥ - 4°C
To < - 4°C
When To is abnormal
Outdoor fan speed (rpm)
Tap
RAS-25PAVSG-ND
W0
0
W1
200
W2
300
W3
300
W4
360
W5
440
W6
500
W7
550
W8
600
Operation flow and applicable data, etc.
YES
fan motor continues.
NO
YES
Air conditioner
NO
In cooling operation
Hz < 13.8
13.8 ≥ Hz < 32.4
Hz < 21.0
21.0 ≥ Hz < 46.2
MIN
MAX
MIN
MAX
W6
WB
W8
WE
W5
WA
W7
WE
W3
W7
W5
W9
W2
W5
W4
W7
W1
W3
W3
W5
W1
W2
W2
W4
OFF
OFF
OFF
W3
OFF
WB
OFF
WE
RAS-35PAVSG-ND
0
200
300
300
360
440
500
550
600
OFF status of
Alarm
OFF
display
Compressor speed
32.4 ≤ Hz
(Hz)
46.2 ≤ Hz
MIN
MAX
WA
WE
To
W9
WE
W7
WB
W6
W9
When To is abnormal
W4
W7
W3
W5
W1
W4
W1
WE
Tap
RAS-25PAVSG-ND
W9
650
WA
700
WB
700
WC
750
WD
750
WE
750
WF
800
- 31 -
FILE NO. SVM-17057
Description
1) The operation command sent
from the remote controller is
processed by the indoor unit
controller and transferred to the
controller of the outdoor unit.
2) When strong wind blows at
outdoor side, the operation of air
conditioner continues with the
fan motor stopped.
3) Whether the fan is locked or not
is detected, and the operation of
air conditioner stops and an
alarm is displayed if the fan is
locked.
4) According to each operation
mode, by the conditions of
outdoor temperature (To) and
compressor revolution, the speed
of the outdoor fan shown in the
table is selected.
In heating operation
RAS-25PAVSG-ND
Hz < 13.8
13.8 ≥ Hz < 32.4
RAS-35PAVSG-ND
Hz < 21.0
21.0 ≥ Hz < 46.2
Fan tap
MIN
MAX
MIN
To ≥ 10°C
W7
To ≥ 5°C
W9
To ≥ -3°C
WE
To ≥ -10°C
WE
To < - 10°C
WE
WE
RAS-35PAVSG-ND
650
700
700
750
800
850
900
32.4 ≤ Hz
46.2 ≤ Hz
MAX
MIN
MAX
W8
W9
WB
WE
WE
WE
WE
WE
WE
WE
WE
WE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-25pavsg-ndRas-35pkvsg-ndRas-35pavsg-nd

Table of Contents