Indoor Fan Motor Control - Toshiba RAS-25PKVSG-ND Service Manual

Hide thumbs Also See for RAS-25PKVSG-ND:
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ °C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
Fan speed
Mode
level
Cool
Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Quiet
Air volume AUTO
M+(WC)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*4
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W7)
from M+ and L)
(Table 1) Indoor fan air flow rate
RAS-25PKVSG-ND
Cooling
Dry
Fan speed
Air flow rate
(rpm)
3
(m
/h)
1030
664
1030
664
1020
UH
657
970
H
620
850
M+
530
800
M
493
750
455
700
L+
416
600
343
590
L
336
580
L-
329
580
UL
329
540
SUL/SL-
299
520
284
500
269
(Fig. 1)
Fan speed
W7
(L + M) / 2
WA
(M + H) / 2
WD
W5
(Fig. 2)
Heating
Fan speed
Air flow rate
Fan speed
(rpm)
3
(rpm)
(m
/h)
1200
1170
789
1200
1170
789
1150
1110
753
1000
1060
643
900
950
568
850
850
530
760
850
463
620
720
358
610
600
351
610
590
351
600
580
343
600
580
343
520
540
284
520
520
284
500
500
269
- 29 -
FILE NO. SVM-17057
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
RAS-35PKVSG-ND
Cooling
Heating
Air flow rate
Fan speed
Air flow rate
3
(rpm)
(m
/h)
1250
768
1250
768
1200
723
1100
686
1000
605
880
530
770
530
620
432
610
343
610
336
600
329
600
329
520
299
520
284
500
269
3
(m
/h)
825
825
789
716
643
552
470
358
351
351
343
343
284
284
269