Panasonic WH-SHF09F3E8 Service Manual page 5

Air-to-water heatpump
Hide thumbs Also See for WH-SHF09F3E8:
Table of Contents

Advertisement

Item
Running Current
Maximum Current For Heat Pump System
Power Factor
Power factor means total figure of compressor and outdoor fan motor.
Power Cord
Thermostat
Protection Device
Item
Performance Test Condition
Operation Range
Internal Pressure Differential
Noise Level
Dimension
Net Weight
Refrigerant Pipe Diameter
Water Pipe Diameter
Water Drain Hose Inner Diameter
Pump
Hot Water Coil
Pressure Relief Valve Water Circuit
Flow Switch
Protection Device
Expansion Vessel
Capacity of Integrated Electric Heater
Note:
Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb
(42.8°F Wet Bulb) with controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
Specification are subjected to change without prior notice for further improvement.
Number of core
Length
Outdoor Ambient
Water Outlet
Height
Width
Depth
Liquid
Gas
Inlet
Outlet
Motor Type
No. of Speed
Input Power
Type
No. of Plates
Size (H × W × L)
Water Flow Rate
Volume
MWP
Unit
A
A
%
m (ft)
Unit
°C
°C
kPa
dB (A)
Power Level dB
mm (inch)
mm (inch)
mm (inch)
kg (lbs)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
W
mm
3
l/min (m
/h)
kPa
A
Residual Current Circuit Breaker / Earth Leakage Circuit Breaker (25)
I
bar
kW
8
4.2
10.8
94
-
-
Electronic Control
Electronic Control
Indoor Unit
EN14511
-20 ~ 35
25 ~ 65
39.8
33
46
892 (35-1/8)
502 (19-3/4)
353 (13-29/32)
48 (106)
9.52 (3/8)
15.88 (5/8)
28 (1-3/32)
28 (1-3/32)
15.00 (19/32)
DC Motor
7 (Software Selection)
60
Brazed Plate
80
130 × 93 × 325
34.4 (2.1)
Open: 300, Close: 265 and below
Magnetic Lead Switch
10
3
9.00
5.6
95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-uh09fe8Wh-shf12f9e8Wh-uh12fe8

Table of Contents