1. Safety Precautions Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating and main circuit for the model installed. ...
Page 3
- Power Supply 1: Use approved 20A 4-poles circuit breaker with a minimum contact gap of 3.0mm. - Power Supply 2: Use approved 15/16A 2-poles circuit breaker with a minimum contact gap of 3.0mm. (Only applicable for WH-SHF09F3E8) or Use approved 20A 4-poles circuit breaker with a minimum contact gap of 3.0mm. (Only applicable for WH-SHF12F9E8) 10.
Page 4
WH-SHF12F9E8 WH-UH12FE8 Item Unit Outdoor Unit Performance Test Condition EN14511 Condition A7W35 A2W35 (Ambient/Water) 12.00 12.00 Heating Capacity BTU/h 41000 41000 kcal/h 10320 10320 4.46 3.26 kcal/hW 3.84 2.80 dB (A) Noise Level Power Level dB Air Flow /min (ft /min) 80.0 (2830) Refrigeration Control Device...
Page 5
Item Unit Running Current Maximum Current For Heat Pump System 10.8 Power Factor Power factor means total figure of compressor and outdoor fan motor. Number of core Power Cord Length m (ft) Thermostat Electronic Control Protection Device Electronic Control Item Unit Indoor Unit Performance Test Condition...
Page 6
3. Features Inverter Technology - Energy saving High Efficiency Compact Design Environment Protection - Non-ozone depletion substances refrigerant (R407C) Long Installation Piping - Long piping up to 30 meter with height difference 20 meter - Flexible 4-way piping for outdoor unit ...
5. Dimensions Indoor Unit <Top View> <Front View> <Side View> 35 98 107 115 155 <Bottom View> 205.5 98.5 Relative position between the indoor unit and the installation plate <Front View> 213.5 213.5 140.7 140.7 Installation 306.4 Plate Indoor unit external dimensions line Unit: mm...
Additional Piping Piping Model Length Elevation Refrigerant Liquid Length Length (g/m) WH-SHF09F3E8 WH-UH09FE8 Ø15.88 mm Ø9.52 mm 5~7.5 (5/8") (3/8") WH-SHF12F9E8 WH-UH12FE8 * If piping length is over common length, additional refrigerant should be added as shown in the table.
14.5 How to Adjust Water Flow Rate [SERVICE MODE: 02] Before adjust the water fl ow rate, make sure that the total water volume in the installation is 50 litres minimum for heating side. The default setting is SPEED 5. Please ensure the minimum fl ow rate is not less than 13 l/min and not more than 50 l/min.
Page 13
18.1.2 WH-SHF12F9E8 WH-UH12FE8 Heating Characteristics at Different Outdoor Air Temperature Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 15.000 14.000 13.000 12.000 11.000 10.000 Outdoor Temperature (°C)
Page 14
Heating Characteristics at Different Piping Length Condition Outdoor air temperature : 7°C (DBT), 6°C (WBT) Indoor water inlet temperature : 30°C Indoor water outlet temperature : 35°C Piping length : 7 m 13.000 12.000 11.000 10.000 9.000 8.000 Piping Length (m) 4.000 3.500 3.000...
18.2 Heating Capacity Table 18.2.1 WH-UH09FE8 Water Out (°C) Input Input Input Input Input Input Capacity Capacity Capacity Capacity Capacity Capacity Outdoor Air (°C) Power Power Power Power Power Power 9000 3460 9000 3710 9000 4010 8800 4260 8600 4610 8500 4910 9000...