Temperature Balancing; Control Characteristics - Viessmann VITOTROL 100 Operating Instructions Manual

Room temperature controller, type utdb-rf, with wireless receiver iu300/ iu301-a10
Table of Contents

Advertisement

Further adjustments

Temperature balancing

If your Vitotrol 100 is installed in an unfavourable posi-
tion, e.g. on an external wall or near an open fireplace,
the displayed room temperature can deviate from the
actual room temperature. You can compensate for this
temperature deviation with a correction value.
Example:
The room temperature displayed by the Vitotrol 100 is
2 °C higher than the actual room temperature. The cor-
rection value is then
2 °C.
01. Open the flap.
02. Press
twice.
03. Use / to select "Settings".

Control characteristics

The hysteresis controller is factory-set. The hysteresis
value influences the start and stop times for "Heating"
or "Not heating".
Example:
Set room temperature: 21 °C
Hysteresis: 0.6 °C (factory setting)
As soon as the actual room temperature exceeds
21.3 °C, heating is stopped. Heating starts as soon as
the actual room temperature falls below 20.7 °C.
You can change the control characteristics by chang-
ing the hysteresis value. Select a lower value if your
system responds too slowly.
1. Open the flap.
2. Press
twice.
3. Use / to select "Settings".
4. Confirm with OK.
5. Use / to select "Service".
6. Confirm with OK.
7. Use / to set the required hysteresis value.
8. Confirm 2 times with OK.
9. Only for the Vitotrol 100, type UTDB-RF:
Exit the menu with
16
.
04. Confirm with OK.
05. Use / to select "Service".
06. Confirm with OK.
07. Use OK to select the required value to be set for
"Ctrller offset".
08. Use / to set the required value.
09. Confirm with OK.
10. Only for the Vitotrol 100, type UTDB-RF:
Exit the menu with
.