Table A-9 Direct Drive Blower Characteristics - 1/2 HP ECM Variable Speed Constant CFM Motor
Furnace Model
UMLV 65-100
SW1 HEAT
DIP SWITCH POSITION
A (1=OFF, 2=OFF)
B (1=ON, 2=OFF)
C (1=OFF, 2=ON)
D (1=ON, 2=ON)
SW2 COOL
DIP SWITCH POSITION
A (1=OFF, 2=OFF)
B (1=ON, 2=OFF)
C (1=OFF, 2=ON)
D (1=ON, 2=ON)
SW2 COOL
DIP SWITCH POSITION
A (1=OFF, 2=OFF)
B (1=ON, 2=OFF)
C (1=OFF, 2=ON)
D (1=ON, 2=ON)
CFM's shown are reduced by 20% if 24 VAC input is to Y1 (slow speed of 2 speed compressor) instead of Y/Y2
SW4 DELAY
DIP SWITCH POSITION
A (1=OFF, 2=OFF)
B (1=ON, 2=OFF)
C (1=OFF, 2=ON)
D (1=ON, 2=ON)
NO ADJUSTMENT
REQUIRED
N/A
APPENDIX A - CHECK OUT AND ADJUSTMENTS
Blower
Motor HP
100-10T DD
1/2 HP ECM
INPUT
CFM WITH SW3-ADJ
[USGPH]
DIP SWITCH POSITION A
0.65
982
0.85
1500
0.75
1170
0.55
852
CONTINUOUS FAN
AC SIZE
CFM WITH SW3-ADJ
[TONS]
DIP SWITCH POSITION A
3.5
700
3
600
2.5
500
2
400
COOLING OR HEAT PUMP HEATING
AC SIZE
CFM WITH SW3-ADJ
[TONS]
DIP SWITCH POSITION A
3.5
1400
3
1200
2.5
1000
2
800
DELAY PROFILE FOR OIL HEATING
INPUT
PRE RUN ON DELAY
[USGPH]
TIME - CFM LEVEL
0.65
60 SECONDS - 0%
0.85
30 SECONDS - 0%
0.75
60 SECONDS - 0%
0.55
60 SECONDS - 0%
DELAY PROFILE FOR COOLING OR HEAT PUMP HEATING
AC SIZE
PRE RUN ON DELAY
[TONS]
TIME - CFM LEVEL
ALL
7.5 MINUTES - 82%
Motor FLA
7.7
OIL HEATING
CFM WITH SW3-ADJ
DIP SWITCH POSITION B
1129
1500
1346
980
CFM WITH SW3-ADJ
DIP SWITCH POSITION B
805
690
575
460
CFM WITH SW3-ADJ
DIP SWITCH POSITION B
1500
1380
1150
920
SHORT RUN ON DELAY
TIME - CFM LEVEL
60 SECONDS - 50%
60 SECONDS - 63%
60 SECONDS - 50%
60 SECONDS - 50 %
SHORT RUN ON DELAY
TIME - CFM LEVEL
NONE
19
∆T
45-75°F
CFM WITH SW3-ADJ
DIP SWITCH POSITION C
835
1275
995
724
CFM WITH SW3-ADJ
DIP SWITCH POSITION C
595
510
425
340
CFM WITH SW3-ADJ
DIP SWITCH POSITION C
1190
1020
850
680
OFF DELAY
TIME - CFM LEVEL
3 MINUTES - 75%
3 MINUTES - 88%
3 MINUTES - 82%
3 MINUTES - 69%
OFF DELAY
TIME - CFM LEVEL
NONE
PN 240010964 Rev. L [10/01/2021]