Table A-3 Riello 40F3 Burner Set-Up
Furnace
Output
Model
BTU/Hr
UML65ARF
66,000
UMLV65ARF
UML80ARF
77,000
UMLV80ARF
UML90ARF
87,000
UMLV90ARF
UML100ARF
97,000
UMLV100ARF
Table A-4 Riello 40BF Burner Set-Up
Output
Furnace Model
BTU/Hr
UML65ARBU
65,000
UMLV65ARBU
UML80ARBU
76,000
UMLV80ARBU
UML90ARBU
86,000
UMLV90ARBU
UML100ARBU
97,000
UMLV100ARBU
Note: Riello 40BF3 burner is required for 0.55 and 0.65 USGPH firing rates. Riello 40BF5 burner is required for 0.75
and 0.85 USGPH firing rates.
APPENDIX A - CHECK OUT AND ADJUSTMENTS
Riello 40F3 Series Oil Burners
(For use with chimney vented units only)
Burner
Delavan
Model
Nozzle
40F3
0.50 / 90°B
VSBT
40F3
0.55 / 80°B
VSBT
40F3
0.65 / 80°B
VSBT
40F3
0.75 / 80°B
VSBT
Riello 40BF3/40BF5 Series Oil Burners
(For use with direct vent units using outdoor combustion air only)
Burner
Delavan
Model
Nozzle
40BF3
0.50 / 90°B
40BF3
0.55 / 80°B
40BF5
0.65 / 80°B
40BF5
0.75 / 80°B
Pump
Flow Rate
Pressure
[USGPH]
[PSIG]
125
0.55
140
0.65
133
0.75
128
0.85
Pump
Flow Rate
Pressure
[USGPH]
[PSIG]
125
0.55
140
0.65
140
0.75
130
0.85
13
Head
Air
Setting
Setting
0
1.6
0
2.1
1
2.5
2
3
Turbulator
Air
Setting
Setting
0.0
4.25
1.0
5.25
0.0
3.75
0.0
4.25
PN 240010964 Rev. L [10/01/2021]