Advertisement

Quick Links

Installation and Operation Manual
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN
THE AREA.
READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD INSERT. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
READ AND KEEP THIS MANUAL FOR REFERENCE
Printed in Canada
CW2900 INSERT
(CB00022 Model)
Safety tested according to
ULC S628, UL 1482 and
UL 737 by an accredited
laboratory.
US Environmental Protection
Agency phase II certified
wood insert compliant with
2020 cord wood standard.
EPA
< ≤
2.5
g/h
46200A
2021-06-22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CW2900 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Century Heating CW2900

  • Page 1 Installation and Operation Manual CW2900 INSERT (CB00022 Model) Safety tested according to ULC S628, UL 1482 and UL 737 by an accredited laboratory. US Environmental Protection Agency phase II certified wood insert compliant with 2020 cord wood standard. < ≤...
  • Page 3 It is also highly recommended to register the warranty online at https://www.century-heating.com/en/warranty/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit. Installation and Operation Manual - CW2900 Page 3...
  • Page 4: Table Of Contents

    PART B - INSTALLATION ......................29 7. Masonry Fireplace Requirements ..................29 7.1 Fireplace and Chimney Condition ..................29 7.2 Chimney Caps .......................29 7.3 Adjacent Combustibles ....................29 7.4 Opening Size .........................29 7.5 Masonry Fireplace Throat Damper ..................29 Page 4 Installation and Operation Manual - CW2900...
  • Page 5 Appendix 6: Air Tubes and Baffle Installation ................46 Appendix 7: Removal Instructions .................... 48 Appendix 8: Exploded Diagram and Parts List ................ 49 CENTURY Limited Lifetime Warranty ..................54 Dealer: Installer: Phone Number: Serial Number: Installation and Operation Manual - CW2900 Page 5...
  • Page 6 OCCASIONNER DES BRÛLURES. BURNS. SEE NAME-PLATE VOIR LES INSTRUCTIONS. AND INSTRUCTIONS. Made in St-Augustin-de-Desmaures (Qc), Canada Fabriqué à St-Augustin-de-Desmaures (Qc), Canada 20/07/2027 ( # 000008 ) 20/07/2027 ( # 000008 ) 27728 Page 6 Installation and Operation Manual - CW2900...
  • Page 7: Part A - Operation And Maintenance

    This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65warnings.ca.gov/ Installation and Operation Manual - CW2900 Page 7...
  • Page 8: General Information

    25%. As measured per CSA B415.1-10 stack loss method. Optimum overall efficiency at a specific burn rate (LHV). This appliance is officially tested and certified by an independent agency. Carbon monoxide. Page 8 Installation and Operation Manual - CW2900...
  • Page 9: Specifications

    CAN/CSA- Z240 MH standard. Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and draft ASTM WK47329-14 Installation and Operation Manual - CW2900 Page 9...
  • Page 10: Dimensions

    14 7/8" 378mm 4" 9 7/8" 251mm 20 3/4" 526mm 22 1/8" 25 5/8" 561mm 26 1/2" 9" 651mm 672mm 228mm 17 1/2" 444mm Front View Side View - Maximum Insert Projection Page 10 Installation and Operation Manual - CW2900...
  • Page 11 561mm 26 1/2" 3/16" 672mm 1/4" 16 1/2" 419mm 11 7/8" 301mm 21" 533mm 14 1/4" 363mm Front View - Combustion Chamber Side View - Combustion Chamber 9" 228mm Installation and Operation Manual - CW2900 17 1/2" Page 11 444mm...
  • Page 12: Epa Certification Loading

    5 min. Then, close the door with the primary air control open. Leave to burn with the primary air control open for approximately 10 minutes and then close the primary air control completely for the low burn rate and halfway for the medium burn rate. Page 12 Installation and Operation Manual - CW2900...
  • Page 13: Materials

    The space where the most time is spent will be warmest, while bedrooms and basement (if there is one) will stay cooler. In this way, less wood is burned than with other forms of heating. Installation and Operation Manual - CW2900 Page 13...
  • Page 14: Emissions And Efficiency

    OF STARTING A FIRE IN AN AFFECTED WOOD; WOOD HEATER. • MANURE OR ANIMAL REMAINS; BURNING THESE MATERIALS MAY RESULT IN THE RELEASE OF TOXIC FUMES OR RENDER THE HEATER INEFFECTIVE AND CAUSE SMOKE. Page 14 Installation and Operation Manual - CW2900...
  • Page 15: Tree Species

    Do not burn compressed logs made of wax impregnated sawdust or logs with any chemical additives. Follow the manufacturer’s instructions and warnings. Installation and Operation Manual - CW2900 Page 15...
  • Page 16: Drying Time

    − Dry wood is much lighter in weight than wet wood, − The face of a fresh cut feels warm and dry; − The moisture content read by a moisture meter is between 15% to 20%. Page 16 Installation and Operation Manual - CW2900...
  • Page 17: Operating The Insert

    «Annexe 1: Ash Lip and Blower Installation»); • Install the faceplate (See «Appendix 2: Faceplate Installation»). The following step is optional : • Install the fresh air intake (See «Appendix 3: Optional Fresh Air Intake Kit Installation»). Installation and Operation Manual - CW2900 Page 17...
  • Page 18: Blower

    Potential causes of smoke spillage are described in Section «10. The Venting System», page 35» of this manual. See «Appendix 4: Optional Fire Screen Installation», page Page 18 Installation and Operation Manual - CW2900...
  • Page 19: Burning Wood Efficiently

    It is possible to use ragged paper but it may not hold in place since it tends to roll while it is burning. The best is to wrap a sheet on itself, grab the ends of the roll and make a knot. Installation and Operation Manual - CW2900 Page 19...
  • Page 20: Combustion Cycles

    This is especially true if the chimney is on the outside wall of the house. If the door must be opened while the fire is flaming, fully open air control for a few minutes then open the door slowly. Page 20 Installation and Operation Manual - CW2900...
  • Page 21: Rekindling A Fire

    No other waste should be placed in this container. NEVER STORE ASHES INDOORS OR IN A NON-METALLIC CONTAINER OR ON A WOODEN DECK. CENDRES ASHES Installation and Operation Manual - CW2900 Page 21...
  • Page 22: Air Intake Control

    Before reducing the air intake, the load will have to burn at full heat for long enough for charring the surface of the logs. The flame must be bright before letting the fire burn by itself. Page 22 Installation and Operation Manual - CW2900...
  • Page 23 East-west loads allow a limited amount of wood since too many logs could cause them to fall on the glass. East-west loads, placed in a compact way, take a long time before breaking down. They are excellent for low-intensity, long-lasting fires in relatively mild weather. Installation and Operation Manual - CW2900 Page 23...
  • Page 24: Maintenance

    The goal should be having a clear glass with no brown stains. If brown stains appear regularly on the glass, something about the fuel or the operating procedure needs to be changed. Page 24 Installation and Operation Manual - CW2900...
  • Page 25 Stick the end of the gasket to the middle of one edge, then press the edge of the glass down onto the gasket, taking care that it is perfectly centred on the gasket. Installation and Operation Manual - CW2900 Page 25...
  • Page 26: Door

    Door gasket when cutting and press the end into the groove. Tuck any loose fibers under the gasket and into the silicone. Close the door. Do not use the insert for 24 hours. Page 26 Installation and Operation Manual - CW2900...
  • Page 27: Exhaust System

    The chimney should be checked regularly for creosote build-up. Inspection and cleaning of the chimney can be facilitated by removing the baffle. See «Appendix 6: Air Tubes and Baffle Installation» for more details. Installation and Operation Manual - CW2900 Page 27...
  • Page 28 Do not use the appliance again until the insert and its chimney have been inspected by a qualified chimney sweep or a fire department inspector. Page 28 Installation and Operation Manual - CW2900...
  • Page 29: Part B - Installation

    If it is removed from the masonry hearth, the notice plate 27009 must be installed in a visible place, inside the masonry hearth. The plate can be found in the owner’s manual kit. Installation and Operation Manual - CW2900 Page 29...
  • Page 30: Safety Information And Standards

    5 of this manual. It will be needed to identify the version of the appliance in the event replacement parts or technical assistance is required. Page 30 Installation and Operation Manual - CW2900...
  • Page 31: Clearances To Combustible Material

    (406 mm USA) and at least 18" (457 mm Canada) without an R value. If the hearth elevation is lower than 4" (102 mm), the non-combustible (B) floor protection in front of the insert should have an R value equal or greater than 1.00 and shall extend 22" (560 mm) in front of the unit. Installation and Operation Manual - CW2900 Page 31...
  • Page 32 R-value, must extend at least 16" (406 mm in USA) or 18" (457 mm in Canada) in front of the unit (B). Refer to «Additional Floor Protection - Raised Installation». Page 32 Installation and Operation Manual - CW2900...
  • Page 33 R value = Thickness/K = 1/0.75 = 1.33 Information as reported by manufacturers and other resources Horizontal still air can’t be «stack» to accumulate R-values; each layer must be separated with another non-combustible material. Installation and Operation Manual - CW2900 Page 33...
  • Page 34: Minimum Masonry Opening And Clearances To Combustibles

    28 7/8" (733 mm) 15 3/4" (400 mm) If a fresh air intake is required, it is recommended to add at least 4" to the width of the minimum opening of the hearth. Page 34 Installation and Operation Manual - CW2900...
  • Page 35: The Venting System

    Otherwise, the diameter of the flue should be 6". The reduction of the liner diameter to less than 6" should only be done if the total height of the masonry chimney is greater than 20 feet. Installation and Operation Manual - CW2900 Page 35...
  • Page 36: Chimney Liner Installation

    The long end of the brackets must be attached to the insert. Insert the chimney liner into the flue collar of the unit and secure the liner to the brackets with three self-tapping screws (not included). Securing the brackets Page 36 Installation and Operation Manual - CW2900...
  • Page 37 The long end of the brackets must be attached to the insert. Then, follow the instructions in the manual provided with the liner offset adapter kit. Securing the brackets Offset liner adaptor Installation and Operation Manual - CW2900 Page 37...
  • Page 38: Minimum Chimney Height

    Even the finest insert will not work well when connected to this chimney. Chimney location in the house Page 38 Installation and Operation Manual - CW2900...
  • Page 39: Supply Of Combustion Air

    Check the outdoor air duct for soot deposits when the full system is cleaned and inspected at least once each year. Installation and Operation Manual - CW2900 Page 39...
  • Page 40: Appendix 1: Ash Lip And Blower Installation

    Before installing the blower, open the door ash shelf. The screws are included in the and install the ash lip by screwing it in place manual kit. with 3 screws, located in the user manual kit. Page 40 Installation and Operation Manual - CW2900...
  • Page 41: Appendix 2: Faceplate Installation

    If necessary, adjust the height of the insert using the levelling bolts (T) on each side of the insert until the faceplate is properly seated on the floor of the hearth extension. Installation and Operation Manual - CW2900 Page 41...
  • Page 42 Then install one faceplate retainer spring on each side of the faceplate and attach the other end of the spring to the brackets on the left and right sides of the insert. Push the faceplate against the fireplace’s front. Page 42 Installation and Operation Manual - CW2900...
  • Page 43: Appendix 3: Optional Fresh Air Intake Kit Installation

    (F) using the other pipe clamp. The outside wall termination must be installed outside of the home. he pipe must be HVAC type, insulated, and must comply with ULC S110 and/or UL 181, Class 0 or Class 1. Installation and Operation Manual - CW2900 Page 43...
  • Page 44: Appendix 4: Optional Fire Screen Installation

    Lift the fire screen upwards and push the bottom part towards the insert then let the fire screen rest on the bottom of the door opening. Warning: Never leave the insert unattended while in use with the fire screen. Page 44 Installation and Operation Manual - CW2900...
  • Page 45: Appendix 5: Log Retainers Installation

    APPENDIx 5: LOG RETAINERS INSTALLATION Installation and Operation Manual - CW2900 Page 45...
  • Page 46: Appendix 6: Air Tubes And Baffle Installation

    Install the baffle. Repeat steps 1 and 2 for the three other tubes. When necessary, remove the tubes using the above steps in reverse order. Page 46 Installation and Operation Manual - CW2900...
  • Page 47 Note that secondary air tubes (A) can be replaced without removing the baffle board (B) and that all tubes are identical. Installation and Operation Manual - CW2900 Page 47...
  • Page 48: Appendix 7: Removal Instructions

    Remove faceplate (B) by pulling on it. Remove the blower assembly (C). Remove the three screws securing the pipe connector (A). Unscrew the bolts securing the insert to the floor on each side of the unit (E). Page 48 Installation and Operation Manual - CW2900...
  • Page 49: Appendix 8: Exploded Diagram And Parts List

    APPENDIx 8: ExPLODED DIAGRAM AND PARTS LIST Installation and Operation Manual - CW2900 Page 49...
  • Page 50 ZINC WASHER 5/16"ID X 3/4"OD 30064 3/16" X 1" CLEVIS PIN 30059 5/32" ID PUSHNUT AC07866 1/4" BLACK COIL HANDLE SE65559 AIR CONTROL ROD ASSEMBLY 30026 THREAD CUTTING SCREW 10-24 F 5/8" HEX WASHER HEAD Page 50 Installation and Operation Manual - CW2900...
  • Page 51 PL74032 BLOWER HOUSING 44080 RHEOSTAT WITHOUT NUT (MODEL KBMS-13BV) 44087 RHEOSTAT NUT 44085 RHEOSTAT KNOB SE74032 BLOWER ASSEMBLY PL74045 FACEPLATE SIDE PANEL PL74044 FACEPLATE TOP PANEL SE74044 REGULAR FACEPLATE (34" X 50") Installation and Operation Manual - CW2900 Page 51...
  • Page 54: Century Limited Lifetime Warranty

    CENTURY HEATING LIMITED WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper installation, lack of maintenance, over firing, negligence or accident during transportation, power failures, downdrafts, venting problems or under-estimated heating area are not covered by this warranty.
  • Page 56 This document is available for free download on the Stove Builder International inc. manufacturer’s website. It is a copyrighted document. 250, rue de Copenhague, Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002...