Fig9-10
Fig 9-11
Step 2
Set the values for Detect Period and Read times of light sensors. Detect Period is the time
period the light sensors measure the environment brightness. Read times of light sensors
is the times that NovaLCT-Mars reads the measurement results of the light sensors. Thus
the auto brightness time interval is the production of Detect Period and Read times of light
sensors. For example, if light sensors measure the environment brightness every 10
second (this is the Detect Period.) and NovaLCT-Mars reads the measurement results of
the light sensors for 5 times (this is the Read times of light sensor.) before adjusting the
LED display brightness, the auto brightness time interval will be 50 seconds.